Residential Wireman Electrical Exam - Larry Bobo With complete solution | Latest 2024/25 RATED A+

Institution
Residential Wireman Electrical
Course
Residential Wireman Electrical









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Residential Wireman Electrical
Course
Residential Wireman Electrical

Document information

Uploaded on
August 15, 2024
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Residential Wireman Electrical Exam -
Larry Bobo With complete solution |
Latest 2024/25 RATED A+
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt
single phase underground dwelling feeder whose ungrounded conductors have been
increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper

Ampacities, Grounding
250.122(B) Table 250.122 Table 8 Ch 9 - 4

The continuity of the grounded conductor shall depend on a busbar or __ only.

Continuity, Grounded conductors
200.12 - wire.

Each multi-wire branch circuit shall be provided with a means that will ____ disconnect
all ungrounded conductors at the point where the branch circuit originates.

Disconnecting means, Branch circuits, multiwire 210.4(B) - Simultaneously

Balconies, decks, and porches that are accessible from the inside of the dwelling unit
shall have at least one receptacle not more than __ ft. above the balcony, deck, or
porch surface.
Balconies, outdoor, receptacles for,
210.52(E)(3) - 6 1/2

Where it is impracticable to locate the service head above the point of attachment, the
service head location shall be permitted not farther than ___ inches from the point of
attachment.
Service drops, Connections, service head
230.54 (C) Exception - 24

True/False: One of the means by which grounding conductors and bonding jumpers
shall NOT be connected by is machine screw type fasteners.

Connection of Grounding and Bonding Equipment 250.8 - False

Cables with entirely nonmetallic sheaths are permitted to enter the top of a surface-
mounted enclosure through one or more nonflexible raceways not less than 450 mm (18
in.) and not more than __ feet in length

Cabinets, Cutout Boxes, and Meter Socket Enclosures. 312.5(C) - 10

, The maximum allowable overcurrent protection for four 14/2 NM cables installed in
contact with thermal insulation without maintaining spacing between cables is:

Nonmetallic-sheathed cable, Insulation, Ampacity,
334.112, 334.80 - 15

What kind of protection is required for an outdoor receptacle located under the soffit of
a dwelling for holiday lighting?

Ground-fault circuit interrupters, Outdoors, dwelling units,
210.8(A)(3) - GFCI

The minimum rating for a service disconnecting means for a building, other than a
single family dwelling, consisting of three 2 wire circuits shall be__ amperes.

Service equipment, Rating,
230.79(D) - 60

Where ungrounded conductors are increased in size, equipment grounding conductors
shall be increased in size ___.

Grounding conductors, 250-III, Sizes, 250.122 250.122(B) - proportionately

True/ False: Unless listed for the control of other loads, general use dimmer switches,
shall only be used to control permanently installed incandescent luminaires.

Dimmers, Switch
404.14(E) - True

In what areas of a dwelling shall 125-volt, single phase, 15 and 20 ampere outlets not
be required to be protected by an arc-fault circuit interupter? Dwellings, Arc-fault circuit-
interrupter protection, 210.12(A) 210.12(A) - Hallways

A ground ring encircling the building or structure, in direct contact with the earth, shall
consist of at least 20 feet of bare copper conductor NOT smaller than __ AWG.

Ground ring
250.52(A)(4) - 2

The minimum size copper equipment grounding conductor required for a 15-ampere
branch circuit installed in rigid metal conduit that supplies a swimming pool pump motor
is __ AWG.

Swimming pools, fountains, and similar installations, 680.21(A)(1) - 12

The maximum allowable ampacity of 18 AWG fixture wire is _ amperes.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUVEX NURSING
View profile
Follow You need to be logged in order to follow users or courses
Sold
733
Member since
2 year
Number of followers
313
Documents
15236
Last sold
1 day ago
STUVATE - STUVIA USA

My store is a comprehensive destination for buying and selling a variety of documents. we offer a vast range of documents that cater to different needs and requirements, our documents are well-researched, accurate, and of high quality, ensuring customer satisfaction. whether you are looking for legal documents, academic papers, business reports or miscellaneous documents we`ve got you covered.

3.8

113 reviews

5
44
4
29
3
23
2
7
1
10

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions