100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

EPA 608 Guaranteed Success

Rating
-
Sold
-
Pages
9
Grade
A+
Uploaded on
06-08-2024
Written in
2024/2025

EPA 608 Guaranteed Success 1. Definition of Reclaiming: - To process refrigerant to a level equal to new (virgin) product specifications as determined by chemical analysis defines: ️ Reclaiming. 2. Disposable Cylinder Disposal Method: - The proper disposal method for disposable cylinders is to ️ recover any remaining refrigerant and then render the cylinder useless, then recycle the metal. 3. Definition of Recycling: - Clean refrigerant for reuse by separating the oil from the refrigerant by passing it through one or more filter driers is the definition of: ️ Recycle. 4. GWP of R-1234ze: - The Global Warming Potential (GWP) of R-1234ze is ️ 0. 5. Hydrostatic Testing Frequency: - Reusable refrigerant containers under high pressure must be hydrostatically tested how often? ️ Every 5 years. 6. Venting Off Refrigerant Vapor: - When filling a charging cylinder with a regulated refrigerant, the refrigerant vapor that is vented off the top must be ️ recovered. 7. Example of Non-condensable: - An example of a non-condensable is ️ air. 8. Vacuum System Safety: - When a system is in deep vacuum, never ️ energize the compressor. 9. HC Refrigerant for Small Appliances: - The HC refrigerant allowed for use in new domestic small appliances is ️ R-600a. 10. Leak Rate Repair Requirement: - Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or greater when the annualized leak rate reaches ️ 30% or more. 11. Refrigerant Trace Gas Release: - What can be done with a refrigerant trace gas and nitrogen mixture after a system leak is found? ️ Release into atmosphere. 12. Classification of Common Refrigerants: - Refrigerants CFC R-12, HCFC R-22, and HFC 134a are all classified as ️ A1. 13. Evacuation Level for R-410A: - When using a recovery unit on a system containing 100 lbs of R-410A, it must be evacuated to: ️ 0" Hg. 14. Dehydration Level: - When dehydrating a system, it should be evacuated to a level of ️ 500 microns. 15. Condensing and Refrigerant Recovery: - Refrigerant should be recovered from the condenser outlet if the condenser is ️ below the receiver. 16. Action for Non-Repairable Leaking Appliance: - If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be ️ retrofitted or retired within 12 months. 17. Recovery Level for Medium Pressure System: - When recovering a medium pressure system with more than 200 lbs of refrigerant, recover to a level of: ️ 15" Hg. 18. Standard for Machine Room Safety: - The standard for machine room safety is ️ ASHRAE 15. 19. Safety Classification of HCFC-123: - The safety classification of HCFC-123 is ️ B1. 20. EPA Evacuation Level for Low Pressure Systems: - The EPA required evacuation level for recovery or recycling equipment used on low-pressure systems is ️ 25 mm of Hg absolute. 21. Equipment for Type III Certification: - What type of equipment can be worked on with Type III certification? ️ Low pressure. 22. Safety Classification of R-134A: - The safety classification of R-134A under ASHRAE Standard 34 is ️ A1. 23. Rupture Disk Burst Pressure: - The rupture disk on a low-pressure chiller has a burst pressure of ️ 15 psig. 24. Maximum Pressure for Leak Detection: - When pressurizing a low-pressure system for leak detection purposes, do not exceed ️ 10 psig. 25. Oil Used in HFC and HFO Systems: - The oil used in HFC and HFO HVACR systems is ️ Esters.

Show more Read less
Institution
Course









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Study
Course

Document information

Uploaded on
August 6, 2024
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

EPA 608 Guaranteed Success


1. Definition of Reclaiming:

- To process refrigerant to a level equal to new (virgin) product specifications as determined by
chemical analysis defines: ✔️ Reclaiming.



2. Disposable Cylinder Disposal Method:

- The proper disposal method for disposable cylinders is to ✔️ recover any remaining refrigerant and
then render the cylinder useless, then recycle the metal.



3. Definition of Recycling:

- Clean refrigerant for reuse by separating the oil from the refrigerant by passing it through one or
more filter driers is the definition of: ✔️ Recycle.



4. GWP of R-1234ze:

- The Global Warming Potential (GWP) of R-1234ze is ✔️ 0.



5. Hydrostatic Testing Frequency:

- Reusable refrigerant containers under high pressure must be hydrostatically tested how often? ✔️
Every 5 years.



6. Venting Off Refrigerant Vapor:

- When filling a charging cylinder with a regulated refrigerant, the refrigerant vapor that is vented off
the top must be ✔️ recovered.



7. Example of Non-condensable:

- An example of a non-condensable is ✔️ air.



8. Vacuum System Safety:

- When a system is in deep vacuum, never ✔️ energize the compressor.

, 9. HC Refrigerant for Small Appliances:

- The HC refrigerant allowed for use in new domestic small appliances is ✔️ R-600a.



10. Leak Rate Repair Requirement:

- Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or
greater when the annualized leak rate reaches ✔️ 30% or more.



11. Refrigerant Trace Gas Release:

- What can be done with a refrigerant trace gas and nitrogen mixture after a system leak is found?
✔️ Release into atmosphere.



12. Classification of Common Refrigerants:

- Refrigerants CFC R-12, HCFC R-22, and HFC 134a are all classified as ✔️ A1.



13. Evacuation Level for R-410A:

- When using a recovery unit on a system containing 100 lbs of R-410A, it must be evacuated to: ✔️
0" Hg.



14. Dehydration Level:

- When dehydrating a system, it should be evacuated to a level of ✔️ 500 microns.



15. Condensing and Refrigerant Recovery:

- Refrigerant should be recovered from the condenser outlet if the condenser is ✔️ below the
receiver.



16. Action for Non-Repairable Leaking Appliance:

- If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be ✔️
retrofitted or retired within 12 months.
$11.30
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
bestscores1 Kent State University
Follow You need to be logged in order to follow users or courses
Sold
12
Member since
1 year
Number of followers
0
Documents
1369
Last sold
3 weeks ago
ReadEase

Welcome to ReadEase, your ultimate resource for exam preparation. At ReadEase, we specialize in providing comprehensive study materials and resources to help you excel in your exams. Whether you're preparing for standardized tests, professional certifications, or academic assessments, our finely curated collection covers a wide range of subjects and levels. From practice tests and study guides to expert tips and strategies, we're here to support your journey to success. ReadEase is committed to availing high-quality educational content, helping you thrive and achieve your academic and professional goals. Have any questions? We're just a message away.

Read more Read less
4.3

4 reviews

5
2
4
1
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions