100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

C.S. Certification Exam, SPD Test, Sterile Processing Study Material for Certification Exam questions and answers rated A+ 2024/2025

Rating
-
Sold
-
Pages
26
Grade
A+
Uploaded on
16-07-2024
Written in
2023/2024

C.S. Certification Exam, SPD Test, Sterile Processing Study Material for Certification Exam questions and answers rated A+ 2024/2025

Institution
Sterile Processing
Course
Sterile Processing










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Sterile Processing
Course
Sterile Processing

Document information

Uploaded on
July 16, 2024
Number of pages
26
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • sterile processing

Content preview

C.S. Certification Exam, SPD Test,
Sterile Processing Study Material for
Certification Exam

Which area is the first to accept responsibility for all supplies in the facility? - ANSReceiving

Which type of inventory distribution system requires the use of a pre-determined inventory
list? - ANSPar Level

Just-in-time distribution systems are also known as - ANSStockless Distribution

Ordering the optimum quantity of an item based on historical data is known as -
ANSEconomical Order Quantity

Which of the following are elements of a distribution system? - ANSpatient charging,
storage, and receiving

The most efficient distribution system is the - ANSTotal exchange cart

The computerized locked supply system is a variation of the - ANSPar Level

Which distribution system requires the using department to be responsible for maintaing
inventory levels? - ANSDemand

An ongoing inventory management system is known as a - ANSPerpetual Inventory System

In which distribution system are requisition filled and delivered as they are received? -
ANSDemand

Inventory performance" (a rough indication of the effectiveness of the inventory system) is
evaluated by - ANSpercent of back order, availability of critical items, and inventory turnover

Which of the following is the MOST efficient and cost-effective method for inventory control
in the SPD ordering and data generation? - ANSComputerized Inventory Control System

The temperature in the sterile storage are should not exceed - ANS75º F (24º C)

Shelving in the sterile storage area must be kept how far from the outside walls? - ANS2
inches

The thickness of a sterility maintenance cover should be - ANS2 to 3 mils

,The minimum number of air exchanges per hour in the sterile storage area should be - ANS4

The relative humidity in the sterile storage area should not exceed - ANS70%

Approximately how much space should be left between and item and the inside edges of a
peel pouch? - ANS1 inch

What is the maximum size and weight of a textile pack? - ANS12" x 12 x 20" 12 pounds

Which of the following packaging materials is acceptable for low-temperature gas plasma
and ozone sterilization - ANSTyvek

Basin sets should be prepared for sterilization with - ANSan absorbent material between
each basin

Tamper-evident seal on rigid containers include - ANSlatches and locks

What is the acceptable temperature range for the prep and packaging area? - ANS68º F-73º
F (20º-23º C)

The preparation and packaging area must have an air exchange rate of - ANS10 per hr

If a non-perforated tray is used for the sterilization of instrument sets, it must be - ANSTilted
on the sterilizer rack

The ideal humidity level in the preparation and packing area should be - ANS50%

For sterilization, rigid containers must be placed - ANSflat

Which of the following packaging materials is acceptable for steam sterilization? -
ANSNon-woven wraps

Re-passivation of an instrument can be achieved by - ANSroutine lubrication

What is the most difficult part of a hemostat to clean? - ANSbox lock

Which of the following lubricants is recommended for use on surgical instruments? -
ANSpetroleum-based

What type of finish on a surgical instrument is used for laser procedures? - ANSebonized

What is the final stage in manufacturing a surgical grade instrument? - ANSpassivation

Which series of stainless steel is used is to manufacture malleable retractors? - ANS300

The weakest part of the instrument is/are the - ANSbox locks

, The layer on a surgical instrument created by the passivation process is called -
ANSchromium oxide

A crack in a hand-held instrument would most likely be found in the - ANSbox lock

The appropriate sterilization cycle for an autoclave load containing a basin set, a minor
surgery set, and twelve towel packs is - ANS270 F (132 C ) for 4 minutes, 30 psi and 20
minutes drying time

Cotton gauze cannot be used in which sterilization process? - ANSlow temperature gas
plasma

Which agencies are involved with the regulation and control of ethylene oxide when it's used
as a sterilant? - ANSenvironmental protection agency, food and drug administration, and
centers for disease control and prevention

Which of the following sterilization methods would be appropriate for petrolatum gauze
dressings? - ANSdry heat

To eliminate the bioburden on metal surgical instrument within the SPD, the MOST
cost-efficient sterilization method is generally considered to be - ANSsteam under pressure

There are two pressure gauges on a steam sterilizer. These gauges measure the pressure in
the - ANSjacket and chamber

What is the maximum number of 100% EO cartridges permitted by OSHA to be stored
outside of a flammable goods cabinet? - ANS10

At the end of the sterilization cycle, the EO cartridges and the gloves used to handle them
should be - ANSAerated

Item to be sterilized in low-temperature gas plasma must be packaged in: -
ANSNon-cellulose-based material

Generally, the EO biological test pack is placed in the - ANSGeometric center of the load

Which of the following devices are compatible with ozone sterilization? - ANSstainless steel
instruments

Routine BI testing for steam sterilizers should be performed at least - ANSweekly

The parameters for low-temperature gas plasma sterilization are: - ANSTime, temperature,
hydrogen peroxide gas plasma

Which of the following can be processed in a low-temperature gas plasma sterilizer? -
ANSlight cords, cameras, and single channel endoscopes

The Action Levels for EO expoure is - ANS0.5 ppm

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Purity96 Howard County Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
79
Member since
2 year
Number of followers
20
Documents
1140
Last sold
3 weeks ago

Welcome to Purity96 ! The place to find the best study materials for various subjects. You can be assured that you will receive only the best which will help you to ace your exams. All the materials posted are A+ Graded. Please rate and write a review after using my materials. Your reviews will motivate me to add more materials. Thank you very much!

3.1

11 reviews

5
4
4
0
3
3
2
1
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions