100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

HESI EXIT EXAM (Newest and Updated Correct Questions and Answers 100% Excel A+ Graded)

Rating
-
Sold
-
Pages
50
Grade
A+
Uploaded on
28-05-2024
Written in
2023/2024

HESI EXIT EXAM (Newest and Updated Correct Questions and Answers 100% Excel A+ Graded) Which change should be made when performing an abdomen radiograph on a patient with ascites? - CORRECT ANSWER-Raise exposure factors. Which system can store images? - CORRECT ANSWER-Picture archival and communication system (PACS). What is the result if pixel bit depth is decreased? - CORRECT ANSWER-Contrast resolution is decreased. Prior to performing a posteroanterior (PA) chest projection with automatic exposure control (AEC), the radiographer discovers that the patient has had a right total pneumonectomy. Which technical consideration should be considered? - CORRECT ANSWER-Selecting only the detector on the left side. Without changing any other factors, which effect is caused by decreasing the field size from 14X17 inches to 8X10 inches? - CORRECT ANSWER-Decrease in the amount of scatter radiation within the part. How often should lead aprons be evaluated to determine if cracks or holes are present? - CORRECT ANSWER-Annually. An increase in which factor will improve spatial resolution? - CORRECT ANSWER-Source to image receptor distance (SID). What is the most likely reason for the increase in quantum noise on a computed radiography (CR) image? - CORRECT ANSWER-Lower than required milliampere-seconds (mAs). Which information in the patient history should prompt the radiographer to decide against using automatic exposure controls when taking a chest x-ray? - CORRECT ANSWER-Emphysema. Which statement is true regarding exposure indicator and the evaluation of digital images? - CORRECT ANSWER-Exposure indicator must be reviewed with every image and must fall within the manufacturer's acceptable range. Which digital communication network is used to store patient billing information? - CORRECT ANSWER-HIS. Which digital post-processing results in a black background surrounding the original collimated edges? - CORRECT ANSWER-Shuttering. Which device temporarily stores an electric charge? - CORRECT ANSWER-Capacitor. What are recommended uses of the digital annotation tool? (Select the four that apply.) - CORRECT ANSWER-Entering technical factors Indicating date or time of the exam Labeling central ray (CR) projection Indicating radiographer performing the exam How does an increase in noise affect the quality of a digital image? - CORRECT ANSWER-Contrast is decreased. Which pathologic condition requires a reduction in exposure factors to produce an acceptable image? - CORRECT ANSWER-Emphysema. The radiographer is using automatic brightness control during fluoroscopy. What change in patient exposure should the radiographer expect as the patient size increases? - CORRECT ANSWER-Increase in exposure. Which calculation is used to determine grid ratio? - CORRECT ANSWER-Height of the lead strips divided by the width of the interspace material. Which is the most likely cause of a histogram error? - CORRECT ANSWER-Selection of an incorrect exam from the look-up table. Picture archiving and communication system (PACS) networks are capable of performing which functions? (Select the two that apply.) - CORRECT ANSWER-Transmitting diagnostic images to remote work stations. Downloading images from different imaging modalities. Who judges radiographic images for quality? (Select the four that apply.) - CORRECT ANSWER-Radiographers Ordering physicians Radiologists Quality control technologists How can magnification of the heart be reduced when performing a chest x-ray? - CORRECT ANSWER-Use a 72-inch source-image-receptor-distance (SID). What is the function of a rectifier? - CORRECT ANSWER-Convert alternating current to pulsating direct current. Which change in technical factors is most likely to result in decreased exposure to the image receptor (IR)? - CORRECT ANSWER-Increased grid ratio Which technique produces a 2 milliroentgens (mR) exposure to an image receptor plate if 70 kilovolts peak (kVp) at 25 milliampere-seconds (mAs) produces 1.6 mR? - CORRECT ANSWER-70 kVp at 31.25 mAs Consider this anteroposterior (AP) mobile chest image. What will improve the photographic quality of this image? - CORRECT ANSWER-Using a grid On which system does hospital staff input new orders for radiologic examinations? - CORRECT ANSWER-Hospital information system. Which part of the x-ray circuit is controlled by adjusting the milliamperage (mA) setting on the operating console for the purpose of producing the heat necessary for thermionic emission? - CORRECT ANSWER-Filament circuit Which standard governs communication between the system that contains the patient's full medical information and the system that has radiology-specific data? - CORRECT ANSWER-Health level 7 (HL-7). Why should computed radiography (CR) image receptors (IR) be erased if they haven't been used? - CORRECT ANSWER-Remove fog from background radiation. Which step will reduce digital image noise, assuming no other changes? - CORRECT ANSWER-Longer exposure time What is the term for the adjustment of image brightness, regardless of exposure received? - CORRECT ANSWER-Rescaling A radiographer is performing a forearm exam on a patient with advanced Parkinson's Disease. Which technical factor adjustments should be used? - CORRECT ANSWER-Decrease the exposure time to reduce risk of patient motion. What is the longest field size dimension allowable for 10 inches by 12 inches collimation at a 40 inch source to image distance (SID)? - CORRECT ANSWER-12.8 inches Which x-ray beam characteristic is reduced by adding aluminum filtration? - CORRECT ANSWER-Quantity of x-rays Which steps increase contrast in fluoroscopy? (Select the two that apply.) - CORRECT ANSWER-Reduce kilovolts peak (kVp) Use a smaller collimator field. X-ray machines are designed to operate at a specific and continuous supply voltage. Which part of the imaging system is responsible for keeping incoming voltage adjusted to the proper value? - CORRECT ANSWER-Line compensator.

Show more Read less
Institution
HESI RADIOGRAPHY 2024
Course
HESI RADIOGRAPHY 2024











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
HESI RADIOGRAPHY 2024
Course
HESI RADIOGRAPHY 2024

Document information

Uploaded on
May 28, 2024
Number of pages
50
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BrooksOfBliss Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
23
Member since
1 year
Number of followers
12
Documents
299
Last sold
4 months ago
Brooks Of Bliss

Thanks in advance. We are pleased to be here just for you. We are offering the Best materials Already Graded A+ 100% Correct for Your Career Excellence in all your Exams. All the best in your study. Message me if you can not find the document you are looking for and i will assist you. Thanks again for purchasing my documents and Review to help others who need the best documents, kindly also refer others so that they can benefit from my documents ._Brooks of Blisss Here For Your Excellency.

Read more Read less
4.3

6 reviews

5
4
4
0
3
2
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions