NFPA 99 2024 Practice Test Questions : Worksheet 1 Questions With Correct Solutions
Categories shall be determined by following and documenting a defined risk assessment procedure. a) True b) False - ANS True 4.2.2 Facility systems in which failure of such equipment is likely to cause minor injury to patients or caregivers shall be designed to meet what category __________? a) 1 b) 2 c) 3 d) 4 - ANS Category 2 4.1.2 What facility, building, or structure is used to house chambers and all auxiliary service equipment for medical applications and procedure at pressures above normal atmospheric pressure. (HYP) a) Hospital b) Hyperbaric c) Hypobaric d) Hypoxia - ANS Hyperbaric 3.3.7.6 What element exists as a colorless, odorless, and tasteless gas at normal atmospheric temperatures and pressure? a) Nitrous oxide b) Liquid oxygen c) Oxygen d) Hydrogen - ANS Oxygen 3.3.126 A warning system within an area uses a ______ that provides continuous visible and audible surveillance of Category 1 and Category 2 medical gas and vacuum systems. a) Alternate Alarm b) Area Alarm c) Local Alarm d) Master Alarm - ANS Area Alarm 3.3.3.1 What warning system is used to monitor the operation and condition of the source of supply of each medical gas and vacuum piping systems? a) Master Alarm System b) Area Alarm System c) Building Management System d) Pressure Indicator System - ANS Master Alarm System 3.3.3.4 A ______ device is used for connecting the outlets of one or more gas cylinders to the central piping systems. a) Mask b) Manifold c) Manufactured Assembly d) Connection - ANS Manifold 3.3.99 What is not part of a typical Category 1 Medical Vacuum System? a) An inlet at locations where patient suction could be required. b) Patient lead. c) Pressure gauges and operating controls. d) Shutoff valves. - ANS Patient lead 3.3.141 What is a pneumatic terminus of a piped gas system for other than critical, continuous duty, nonflammable medical life support-type gases? a) Compressor b) Service inlet c) Service outlet d) Vacuum outlet - ANS Service outlet 3.3.164 A D.I.S.S. connector is a system of ______ medical gas and vacuum connectors complying with CGA V-5. a) Double insulated b) Emergency c) Interchangeable d) Non-Interchangeable - ANS Non-Interchangeable 3.3.43
Written for
- Institution
- Medical Gas
- Course
- Medical Gas
Document information
- Uploaded on
- May 14, 2024
- Number of pages
- 7
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
nfpa 99 2024 practice test questions worksheet 1
Also available in package deal