Family of burrs provides maximum visibility due to the following - ANSclearshroud/hood
The power pick instrument was initially designed to do - ANSmicro fracture procedures
The torpedoes shaver had which of the following features - ANSA tapered cottical tip
T/F the power rasp attachment is a motion device that creates a smooth flat surface - ANSFalse
Which shaver oscialtes by its most agressive tissue resection and control - ANSAgg (agressive)
How many hand pieces can be connected and controlled simultaneously by the synergy
resection console? - ANS2
What is the largest arthroscopic section for the bipolar RF Products? - ANSShoulder
The bipolar ablation breaks down tissue by the following process? - ANSChemical reaction
The metal detection feature on the synergy fr bipolar ablation system performs what function? -
ANSSuspends power to the probe when the tip is in close proximity of the scope or metal
instruments
When using bipolar RF technology, the clinical guidelines include? - ANSAll of the above
The default ablation setting levels for the mp90 probe is? - ANS7 Ablation
The 3 biproducts of ablation are? - ANSBubbles, Frictional Heat, Light emission
What are some techniques surgeons use the rf bipolar wands for? - ANSAll of the above
T/F when removing the orange cap and plugging in the pressure sensor is the first step into your
set up procedure for the dual wave arthroscopy? - ANST
The purpose of the shaver boost mode on the dual wave arthroscopy pump is? - ANSIncrease
the pressure when shaver is activated
T/F The dual wave arthroscopy pump is designed to opperate as either inflow-outflow or an
inflow only pump? - ANST
If the dual wave arthroscopy pump height is 1ft above the operative site what is the differential
btw the displayed pressure and actual pressure? - ANS22mmhg
, The main talking points in introducing the synergy Uhd imaging platform? - ANSAll of the above
What type of light engine is in the synergy uhd4 all in 1 camera system? - ANSLED
What are the fluid management options the nanoscope operative arthroscopy system? -
ANSSyringe, gravity, and pump systems
The target used space for the nanoscope operative arthroscopy system include? - ANSClinic,
Procedure Rooms, ORs
The nanoscope operative arthroscopy system differs from its competitors all of the following
ways except? - ANSOffering the camera with the smallest diameter
Surgical repair of the lateral ankle ligament of the Atfl is most often accomplished with what
procedure? - ANSThe modified brostrum gold procedure
When someone suffers an ankle sprain what ligament is involved most commonly? - ANSATFL
(Anterior Talo-Fibula Ligament)
T/F Arthrex recommends using the IB implant for later ankle instability with or without a repair of
the Atfl? - ANSF
T/F the 4.75mm Swivelock anchor for lateral ankle instability is recommended to be placed in
the Talus however the surgeon can place it in ? As they wish? - ANST
T/F the internal brace implants allows for earlier weight bearing while protecting the ligament
repair? - ANST
What is the Arthrex suggested technique on fibertape suture positioning for IB augmentation? -
ANSTalus to fibula over the top of the ATFL repair
Which of the following plates contains features to accommodate the syndesmosis tightrope
implant? - ANSAll of the above
Where is a Weber B fracture located? - ANSFracture Joint Line
What year did Arthrex launch the ankle syndesmosis tightrope implant? - ANS2005
Which of the following is currently available size of the fibulock nail? - ANS130 x 3.8mm
Which of the following differentiating property of the fibulock nail from other fibular nail? -
ANSProximal fixation