F-60 FIRE GUARD Exam 2024 Questions & Answers Solved 100% Correct!!
THE COF HOLDER MUST KEEP THE COF ___________ OR READILY AVAILABLE FOR INSPECTION - AnswerUPON HIS OR HER PERSON PORTABLE LPG CONTAINERS THAT ARE MORE THAN ________ MUST NOT BE STORED, HANDLED, OR USED INDOORS. - Answer-16.4 OZ PERMITS SHALL BE READILY AVAILABLE ON THE _________ FOR INSPECTION BY FIRE DEPARTMENT REPRESENTATIVES. - Answer-PREMISES HOT WORK PERMITS SHALL BE AVAILABLE FOR INSPECTION BY ANY REPRESENTATIVE FOR __________ AFTER THE WORK IS COMPLETE. - Answer-48 HOURS FOR _____________, THE OWNER OF THE HOT WORK OPERATION AREAS MUST BE NOTIFIED IN WRITING BY THE CITYWIDE PERMIT HOLDER AT LEAST 48 HOURS BEFORE HOT WORK IS TO BE STARTED. - Answer-CITYWIDE HOT WORK OPERATIONS PRE-HOT WORK CHECKS MUST BE CONDUCTED BEFORE HOT WORK IS AUTHORIZED AND AT LEAST ___________. - Answer-ONCE PER DAY FIRE WATCH WILL BE PROVIDED FOR A MINIMUM OF _________ AFTER WORK IS COMPLETE. - Answer- 30 MINUTES HOT WORK AREAS MUST BE KEPT ___________ FEET AWAY FROM ANY COMBUSTIBLE MATERIAL. - Answer-35 PAPER, WOOD SHAVINGS, STRAW AND FABRIC ARE EXAMPLES OF ______________. - AnswerCOMBUSTIBLE MATERIAL THE ENTIRE WORK AREA SHOULD BE CHECKED AFTER COMPLETION OF HOT WORK FOR __________. - Answer-FIRESA MINIMUM ____________ RATING FIRE EXTINGUISHER MUST BE READILY ACCESSIBLE. - Answer-2- A:20-B:C THE FIRE EXTINGUISHER MUST BE ACCESSIBLE WITHIN __________ FEET OF HOT WORK LOCATION AND FIRE GUARD. - Answer-30 FOR TORCH-APPLIED ROOF SYSTEMS, A MINIMUM ___________ RATING FIRE EXTINGUISHER MUST BE READILY ACCESSIBLE. - Answer-3-A: 40-B:C ___________ PROTECTION SYSTEMS SHALL NOT BE SHUT OFF WHILE HOT WORK IS PERFORMED. - Answer-AUTOMATIC SPRINKLER COMPRESSED GAS CONTAINERS MUST BE REPLACED WHEN ___________. - Answer-THEY ARE EMPTY EMPTY CONTAINERS MUST BE HANDLED IN THE SAME MANNER AS ____________. - Answer-FULL ONES A ___________ MUST NOT BE ROLLED ON ITS SIDE OR ITS RIM. - Answer-COMPRESSED GAS CONTAINER THE TOP OF THE FIRE EXTINGUISHER MUST NOT BE MORE THAN ________ FEET ABOVE THE FLOOR, NOR THE BOTTOM OF THE FIRE EXTINGUISHER BE LESS THAN _________ INCHES FROM THE GROUND. - Answer-5, 4 THE COF HOLDER SHOULD ONLY CONSIDER EXTINGUISHING FIRES WHEN THEY ARE ____________. - Answer-LIMITED IN SIZE NEVER APPROACH A FIRE FROM A __________. - Answer-DOWNWIND DIRECTION DO NOT DIRECT THE CHEMICAL STREAM AT THE ________. - Answer-CENTER OF THE FLAME FOR ________, THE GAS SUPPLY MUST BE SHUT OFF FIRST AND THEN CALL 911. - Answer-PIPED GASWHEN NOT POSSIBLE TO SHUT OFF GAS SUPPLY, ALLOW THE FLAME TO ___________ AND CALL 911. - Answer-BURN ITSELF OUT CLASS A EXTINGUISHERS ARE FOR EXTINGUISHING ___________. - Answer-ORDINARY COMBUSTIBLES CLASS B EXTINGUISHERS ARE FOR EXTINGUISHING ___________. - Answer-FLAMMABLE OR COMBUSTIBLE LIQUIDS CLASS C EXTINGUISHERS ARE FOR EXTINGUISHING _____________. - Answer-ELECTRICAL EQUIPMENT CLASS D EXTINGUISHERS ARE FOR EXTINGUISHING ____________. - Answer-IGNITABLE METALS FIRE EXTINGUISHERS ARE REQUIRED TO INSPECTED __________. - Answer-MONTHLY FIRE EXTINGUISHERS MUST BE MAINTAINED BY A FDNY APPROVED COMPANY AT LEAST ___________. - Answer-ONCE PER YEAR
Written for
- Institution
- F-60 FIRE GUARD
- Course
- F-60 FIRE GUARD
Document information
- Uploaded on
- April 19, 2024
- Number of pages
- 3
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
Also available in package deal