Maryland Asbestos Test Study Guide 2024/2025
Maryland Asbestos Test Study Guide 2024/2025 Category 1 nonfriable asbestos-containing material (AMC) - CORRECT ANSWERmeans asbestos-containing packages, gaskets, resilient floor covering, and asphalt roofing products containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CRF part 763, section 1, Polarized Light Microscopy Category II nonfiriable AMC - CORRECT ANSWER-means any material, excluding Category I nonfirable AMC, containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CRF part 763, section 1, Polarized Light Microscopy that , when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure Demolition - CORRECT ANSWER-means the wrecking of tacking out of any loadsupporting structural member of a facility together with any related handling operations or the international burning of any facility Friable asbestos material - CORRECT ANSWER-means any material containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CRF part 763, section 1, Polarized Light Microscopy that , when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. If the asbestos content is less than 10 percent as determined by a method other than point counting by polarized light microscopy (PLM), verify the asbestos content by point counting using PLM. Regulated asbestos-containing material (RAMC) - CORRECT ANSWER-means (a) Friable asbestos material, (b) Category I nonfriable AMC that has become friable, (c) Category I nonfirbale AMC that will be or has been subjected to sanding, grinding, cutting, or abrading, or (d) Category II Nonfirable ACM that has become crumbled, pulverized, or recorded, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations regulated by this subpart Renovations - CORRECT ANSWER-means altering a facility or one or more facility components in any way, including the stripping or removal of RAMC from a facility component. Operations in which load-supporting structural members are wrecked or taken out of demolitions. Visible emissions - CORRECT ANSWER-means any emissions, which are visually detectable with out the help of instruments, coming form RAMC or asbestos-containing waste material, or form any asbestos milling, manufacturing, or fabricating operations. This does not include condensed, uncombined water vapor 61.145 Standard for demolition and renovation (a) 1 (i) - CORRECT ANSWER-At least
Written for
- Institution
- Asbestos supervisor
- Course
- Asbestos supervisor
Document information
- Uploaded on
- April 17, 2024
- Number of pages
- 8
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
- industrial building
-
maryland asbestos test study guide
-
category 1 nonfriable asbestos containing material
-
61145 standard for demolition and renovation a
Also available in package deal