ABSA 5th Class Questions with 100% Correct Answers
ABSA 5th Class Questions with 100% Correct Answers Where are the return openings located regarding air distribution systems? -answerReturn air openings are located on inner walls. The minimum temperature of the water used in a hydrostatic test of a boiler cannot be less than what temperature? -answer20 degrees Celsius Which of the following are causes of pressure explosions? 1. effects of corrosion 2. weak pilot flame 3. stressed material due to heating too quickly 4. insufficient purge 5. scale and sludge build-up -answer1, 3, 5 Carbon, which is not combined with hydrogen, is referred to as: -answerFixed Carbon Maximum static pressure in a fuel oil line is approximately: -answer35 kPa Combustion of a fuel in a boiler furnace: -answershould be performed with a minimum of excess air What is a hydrostatic test? -answerA way in which pressure vessels can be tested for strength and leaks. How often do burner and fan motors which uses standard bearing normally require lubrication? -answerYearly On a hot water boiler, the pressure differential between the operating pressure and the safety relief valve set pressure must be (at a minimum): 1. 25% of operating pressure 2. 125% of operating pressure 3. 69 kPa 4. 25% of the safety relief valve set pressure -answer3, 4 In hot water boiler operation the maximum operating temperature should never exceed: - answer121 degrees celsius A substance, which will absorb humidity inside a boiler during dry lay up is: - answerActivated alumina When draft is produced by natural means: -answercooler air surrounding the boiler increases draft Coal is composed of the following combustible components: -answerCarbon, hydrogen, Sulphur Which of the following are causes of furnace explosions? 1. main fuel valve closed when the burner flame is lost 2. insufficient purge 3. burners lit from hot refractory 4. effects of corrosion 5. admission of fuel before ignition source -answer3,4,5 Which grade of oil is the most popular for domestic and small commercial boilers? - answerGrade 2 The inclined manometer as compared to the U manometer is what? -answerMore accurate. How can the draft through a natural draft furnace be increased? -answerIncrease the temperature of the stack The main function of a gas burner is: -answerprovision of O2 - fuel contact The minimum distance from furnace to oil storage tank is: -answer2 feet One of the main component of an electric ignition system is the step-up transformer which takes 120 V and boosts it to _____ volts -answer10,000 - 12,000 volts. Combustion of a fuel in a boiler furnace should be performed in what conditions? - answerThere should be a minimum of excess air. What type of oil burner is used when oil is supplied under high pressure? - answerMechanical Atomizing Burner An air atomizing compressor is usually what type? -answerA rotary type. Which of the following advantages does oil have over coal as a boiler fuel? 1. requires less storage space 2. costs less to handle 3. fuel quantity is easier to control 4. burns more cleanly -answerAll of the above In a boiler burner with 3 fixed capacity nozzles,the intermediate and high burner nozzles have higher capacities than the primary burner nozzle for what reason? -answerTo allow better boiler warm-ups What is a manometer used for? -answerMeasure draft A draft gauge on a furnace indicates the draft in: -answermm of water column
Written for
- Institution
- ABSA
- Course
- ABSA
Document information
- Uploaded on
- April 9, 2024
- Number of pages
- 26
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
absa 5th class questions with 100 correct answers
Also available in package deal