EPE3701 power engineering systems Assig 1 2024

Rating
-
Sold
-
Pages
9
Uploaded on
08-04-2024
Written in
2023/2024

QUESTION 1 [22] A three-phase synchronous generator with negligible armature resistance has synchronous reactance Xs = 1.65 p.u. and is connected to a very large system. The terminal voltage is 1.0 p.u. and the generator is supplying to the system a current of 0.9 p.u. at 0.85 p.f. (lag). Determine: 1.1 The magnitude and angle of the internal voltage, E; (4) To determine the magnitude and angle of the internal voltage, E, we can use the equation: E = V + I*Xs Where: V = terminal voltage = 1.0 p.u. I = current supplied to the system = 0.9 p.u. at 0.85 p.f. (lag) Xs = synchronous reactance = 1.65 p.u. First, we need to convert the current to its rectangular form: I = 0.9 ∠ -31.8 degrees......

Show more Read less
Institution
Course









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Course

Document information

Uploaded on
April 8, 2024
Number of pages
9
Written in
2023/2024
Type
Other
Person
Unknown

Subjects

Content preview

2024





POWER ENGINEREERING
SYSYTEM (EPE 3701)




JNY-LX1
EPE3701 Power Engineering Systems
Welcome to the EPE3701 assessment
1/minor test 1. Date: 2024-03-25 Time:
08:00 Hours: Examiner name: TS Hlalele
External moderator name: PT Manditereza
This paper consists of 3 pages including
cover page. Total marks: 42 due
09/APRIL/2024 11:pm
4/9/2024

, COMPLEETE ANSWERS

 100 % TRUSTED WORKINGS

 EXPLANATIONS AND SOLUTIONS

 ALL QUESTIONS ANSWERED FOR YOU




QUESTION 1

[22] A three-phase synchronous generator with negligible armature resistance
has synchronous reactance Xs = 1.65 p.u. and is connected to a very large
system. The terminal voltage is 1.0 p.u. and the generator is supplying to the
system a current of 0.9 p.u. at 0.85 p.f. (lag). Determine: 1.1 The magnitude
and angle of the internal voltage, E; (4)



To determine the magnitude and angle of the internal voltage, E, we can use the
equation:

E = V + I*Xs



Where:

V = terminal voltage = 1.0 p.u.

I = current supplied to the system = 0.9 p.u. at 0.85 p.f. (lag)

Xs = synchronous reactance = 1.65 p.u.



First, we need to convert the current to its rectangular form:

I = 0.9 ∠ -31.8 degrees

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
jenniferrichards University of South Africa (Unisa)
Follow You need to be logged in order to follow users or courses
Sold
1039
Member since
3 year
Number of followers
677
Documents
268
Last sold
3 months ago

4.3

108 reviews

5
65
4
21
3
12
2
8
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions