PA INSPECTION AND TESTING QUESTIONS AND ANSWERS 100% CORRECT .Test probes and leads for safe isolation must comply with - ANSWER-Gs38 .To ensure all systems within a building work as they were intended is one deinition of the purpose of - ANSWER-Commissioning electrical systems .What is required before inspection can be carried out - ANSWER-Earthing system Maximum demand Supply characteristics .Most important to verify initial verification - ANSWER-Basic protection Equipment suitability Termination of conductors and cable selection .Most important in establishing safety - ANSWER-Fault protection Basic protection .First test on initial verifacation - ANSWER-Continuity of protective conductors .What voltage used when calculating resistance of supplementary bonding conductors - ANSWER-50 v .Testing 230v installation, insulation resistance tester must be set to a voltage of... - ANSWER-500v .Value of a satisfactory insulation resistance test on each final circuit of a 230v installation must be - ANSWER-No less than 1Mohm .Instrument calibration certifates valid.. - ANSWER-1 year .Correct order for requirements regarding dead test - ANSWER-CIP (alphabetical order) .To obtain R1 + R2 in a ring circuit the R1 + R2 measurements need to be - ANSWER-Divided by a factor of 4 .For pvc flat profile cables aside from 1mm2 the resistance value of the live conductors with the respect to cpc is equivalent to - ANSWER-Ratio of 1.67, readings MORE than line and neutral conductors .One objective of dead polarity test is to verify - ANSWER-Lamp holders centre contact is connected to line conductor .Connecting circuits in parallel will - ANSWER-Reduce total resistance .Increasing length of circuit will - ANSWER-Reduce its insulation resistance .What should be considered before insulation resistance test - ANSWER-All loads and capacitors removed Value of supply voltage .Definition of polarity - ANSWER-Functional switching takes place thought the line conductor .Total earth loop impedance can be obtained by - ANSWER-Measuring Zs Measuring Ze and R1 and R2 Inquiry of ze and measuring of R1 and R2 .Live polarity tests are carried out by connecting across which line conductors - ANSWER-Line and line .To ensure breaking capacity of a cb is met what human senses should be used - ANSWER-Touch and sight .Recommended maximum inspection and re test for a domestic electrical installation is - ANSWER-10 years .What should be issued after the completion of two small additions to and excising circuit - ANSWER-Minor works .Following completion of a new installation what must be issued - ANSWER-Electrical installation certificate .Following completion of an installation - ANSWER-Inspector keeps copy Customer given copy .To confirm isolation has been achieved tests must be carried out on - ANSWER-All live conductors and earth .When does inspection of a new installation begin - ANSWER-When construction starts .Information on requirements for testing can be found in bs7671 part - ANSWER-6 .BS7671 identifies requirements for initial verification in chapter - ANSWER-61 .Supplementary bonding conductors should be inspected to ensure they connect - ANSWER-Exposed and extraneous conductive parts .Maximum distance from any corner of a wall for prescribed zone is - ANSWER-150mm .Inspection of appropriate functional switching devices would include a - ANSWER-Light switch .Total number or tests when confirming safe isolation of a three phase and neutral isolator - ANSWER-10 .What appendices can the standard forms of certifications be found in - ANSWER-6 .Document on completion of periodic inspection - ANSWER-Electrical installation condition report .Correct colour of line conductors on a single phase circuit - ANSWER-Brown .Flat profile twin and circuit protective conductor cable without mechanical protection concealed within the walls of a dwelling should be inspected to ensure they are in prescibef zones and protected by - ANSWER-30 amp residual device .Inspection of appropriate devices for isolation and switching would include a - ANSWER-Main isolator .When testing continuity the resistance of the test leads should be nulled or - ANSWER-Subtracted from the results .Reg 13 - ANSWER-Precautions for work on equipment made dead .Reg 14 - ANSWER-Work on or near live conductors .Reg 15 - ANSWER-Working space access and lighting .Reg 16 - ANSWER-Persons to be competent to prevent danger .Initial verifacation - ANSWER-During erection/completion of an installation or an addition before it's put into service appropriate inspection and testing should be put into place To verify that a new electrical installation complies with the design and is sage to place into service .Safe isolation procedure - ANSWER-Permission Select approved lamp or testing device Locate and identify equipment being worked upon Identify means of isolation Subside isolation of circuit

Show more Read less
Institution
PA INSPECTION
Course
PA INSPECTION









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
PA INSPECTION
Course
PA INSPECTION

Document information

Uploaded on
March 25, 2024
Number of pages
12
Written in
2023/2024
Type
Exam (elaborations)
Contains
Unknown
$6.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
stuviaAgrade

Also available in package deal

Thumbnail
Package deal
PA Questions and Answers 100% correct
-
4 2024
$ 25.66 More info

Get to know the seller

Seller avatar
stuviaAgrade Harvard University
View profile
Follow You need to be logged in order to follow users or courses
Sold
0
Member since
2 year
Number of followers
1
Documents
425
Last sold
-
WISDOM SEEKERS

On this page, you find all documents, package deals, and flashcards offered by seller StudentsOnly.

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions