100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

ABYC Systems Exam Questions and Answers 100% Correct

Rating
-
Sold
-
Pages
26
Grade
A+
Uploaded on
14-03-2024
Written in
2023/2024

B - ANSWER -Tubes are measured by: A. ID B. OD C. nominal size C - ANSWER -pipes may not be connected by: A. Welding B. Threaded fittings C. Compression fittings D. Glue C - ANSWER -Tech A says Seacocks must be readily accessible. Tech B say its ok to have them within 12" of the engine. who is correct? A. Tech A B. Tech B C. Both D. neither D - ANSWER -Tech A says that it is all right to connect an auxiliary line to the potable water pump as long as there is a siphon break. Technician B says you must have a lockable Y valve to prevent cross contamination. who is right? A. Tech A B. Tech B C. Both D. Neither D - ANSWER -A bildge pump discharge line must be:

Show more Read less
Institution
ABYC Systems
Course
ABYC Systems










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ABYC Systems
Course
ABYC Systems

Document information

Uploaded on
March 14, 2024
Number of pages
26
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ABYC Systems Exam Questions and Answers 100% Correct
E - ANSWER -Ball valves may be sealed to through hull fittings with:
A. 5200 B. SikaFlex
C. Teflon D. All the above E. None of the above
B - ANSWER -Tubes are measured by: A. ID B. OD C. nominal size
C - ANSWER -pipes may not be connected by: A. Welding B. Threaded fittings C. Compression fittings D. Glue
C - ANSWER -Tech A says Seacocks must be readily accessible. Tech B say its ok to have them within 12" of the engine. who is correct? A. Tech A B. Tech B C. Both D. neither
D - ANSWER -Tech A says that it is all right to connect an auxiliary line to the potable water pump as long as there is a siphon break. Technician B says you must have a lockable Y valve to prevent cross contamination. who is right? A. Tech A B. Tech B C. Both D. Neither
D - ANSWER -A bildge pump discharge line must be: A. equipped with a check valve to prevent back flow and nuisance cycling B. Equipped with a properly installed seacock C. No more than 30' long D. non of the above
D - ANSWER -ball valves below the waterline must be: A. ABYC approved B. ABYC Certified C. ABYC endorsed D. none of the above
D - ANSWER -potable water systems must discharge
A. into a sump B. Overboard C. Into the grey water tank D. any of the above
OD ID - ANSWER -Tubes are measured in _________ and hoses are measured in _________
A - ANSWER -Which of the following components may need to be by-passed for the purpose of decommissioning? A. Tanks, filters and water heaters B. Strainers, tanks and pumps C. Fixtures and lines D. Dockside water connections
B - ANSWER -Which of the following agencies must be referenced when selecting materials for use in a portable water system? A. DOT B. FDA C. USCG D. UL
B - ANSWER -According to ABYC, a biologically contaminated potable- water system should be disinfected with a mixture of chlorine and have a strength of at least: A. 1,00ppm B. 100ppm C. 10ppm D. 1 ppm B - ANSWER -Contamination of the potable-water system with ethylene glycol may be explained by: A. Excessive pump cycling B. Leaking heat exchanger on a water heater C. Nuisance tripping of pump circuit breaker D. Close proximity of engine to water heater
A - ANSWER -With a Type 1 sanitation system, waste is: A. Treated and discharged B. Treated and held C. Stored in a holding tank D. Discharged without treatment
A - ANSWER -A head located below the vessels's dynamic waterline using RAW water for flushing requires a: A. Vented loop on its intake B. Check valve on its intake C. Strainer on its intake D. Check valve on its discharge
A - ANSWER -The result of an obstructed holding tank even during pump out may be: A. A collapsed holding tank B. Raw water flooding C. An explosion D. Tank contamination
D - ANSWER -Which of the following sanitation pumps could run dry without damage? A. Centrifugal B. Flexible impeller C. Vane D. Diaphragm
B - ANSWER -The design and location of the vent for a potable water tank must prevent
the ingress of all of the following EXCEPT
A. Sea water B. Air C. Insects D. Bilge water

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Topgrades20 West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
12
Member since
2 year
Number of followers
10
Documents
812
Last sold
9 months ago

3.5

2 reviews

5
0
4
1
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions