ICC Service Technician Study Guide Questions & Answers Latest Version Updated 202425
ICC Service Technician Study Guide Questions & Answers Latest Version Updated 202425 According to CCR, Title 23 UST Regulations, What is the frequency that the Monitor Certification must be performed? Every 12 Months If visual monitoring is utilized as the means of release detection for single walled tank, it must be conducted on a _______ Basis. Daily The Purpose of spill and overfill protection equipment is to minimize the potential for a release during: Fuel Deliveries Which of the following is a potential symptom of toxic petroleum exposure: Dizziness Tremors Eye irritation All of the above(correct) Under-Dispenser Containment is required for ______ underground storage tank systems All All of the following are true for Automatic Tank Gauging (ATG) except for: ATG system are required to be installed in all UST system According to CCR Title 23, UST regulations Spill containment (spill bucket) must meet all of the following requirements except: Be installed on vent risers Suction piping may not require leak detection if it has one check valve located where? Directly below the suction pump Service Technician performing work on Monitoring equipment must be trained and certified by __________ The manufacture of the equipment. Air monitoring must be conducted ________ when performing work within a confined space. Prior to and during A UST Service Technician must be recertified by the equipment Manufacture at the time interval recommended by the equipment manufacture or at least every ____ months, whichever is greater. 36 Months When an automatic tank gauge is utilized for single-walled tank leak detection, it shall test the tank at least monthly after product delivery or when the tank is filled to within _____ percent of the highest operating level during the previous month. 10 The following is true of spill buckets except: Must provide drainage for spilled product into the secondary containment sump. If during an inspection of dispensing equipment at a retail gas station you find that the product is dispensing at a significant lower rate than usual. You should check: For piping leaks. According to CCR title 23, UST Regulations the local agency must be notified by the Owner/Operator how long before conducting Secondary Containment Testing? At least 48 hours before the test. Poppet Valves are a Vapor Recovery Component installed: on the vapor recovery riser If equipped with an ATG it shall be programmed to test the tank _______? at least monthly A Vacuum-assist nozzle is a component of a(n) ________? Stage II vapor recovery system Stage I Vapor Recovery can be installed in the following configured(s): Dual Point, Manifold, & Coaxial An Underground tank System includes: The underground storage tank Piping Ancillary Equipment All of the above is correct If equipped with an overfill alarm, the alarm must be triggered to alert the delivery operator when the tank is no more than _______ full. 90% Approved Cathodic Protection Methodologies include: Sacrificial Anodes, & Impressed current system _________is a system for exchanging gasoline vapors in a storage tank(s) and product in a fuel delivery truck. Stage I Recovery Automatic Line Leak Detectors, installed on Underground Piping with Secondary Containment. Shall be capable of detecting a leak of _______ at 10 PSI. 3 gallons per hour (GPH) The fastest exposure for Petroleum Toxicity to affect the body is through: Inhalation (Through breathing) According to California Health and Safety Code for Underground Storage of Hazardous substances, An "underground storage tank" is defined as: An underground tank and connecting piping. For existing UST's using Automatic tank Gauges as the sole means of quantitative release detection, the ATG, must be capable of detecting a release of ______ gallons per hour. 0.2 GPH In case of gasoline, it is the _______ that pose(s) a threat of combustion. Vapors A liquid collection point is a small reservoir designed to collect ______ without obstruction of the vapor pipe pathway. Gasoline What does the Tank Interstitial Sensor monitor: The space between the inner and outer walls. Automatic Line Leak Detectors are required on: Pressurized Piping The local agency may wave the requirements for overfill protection if the UST is filled by transfer of less than: 25 Gallons Under Dispenser Containment is a device that is capable of preventing an unauthorized release from the dispenser from entering ______: The soil and groundwater. The definition of "Hazardous" is any substance, situation or condition that is capable of causing: Harm For the purpose of gathering statistical inventory reconciliation data, tanks must be disputed on a _______ basis. Daily Results of Enhanced Leak Detection testing must be submitted to the State Water Resource Control Board within ______ days. 60 Days
Written for
- Institution
- ICC Service Technician
- Course
- ICC Service Technician
Document information
- Uploaded on
- March 13, 2024
- Number of pages
- 8
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
icc service technician study guide questions ans
Also available in package deal