100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Journeyman Plumbing Test Study Guide With Latest Solutions

Rating
-
Sold
-
Pages
19
Grade
A+
Uploaded on
07-03-2024
Written in
2023/2024

Journeyman Plumbing Test Study Guide With Latest Solutions more restrictive provisions apply - answerwhere conflicts occur between code and manufacture instructions. what shall be 3rd party certified as conforming to NSF 14 - answerall plastic pipe, fittings and components. all strainer plates on drain inlets shall be designed and installed so that all openings are..? - answernot greater than 1/2 inch (12.7) in least dimension. pipes through foundation walls need..? - answera relieving arch or a pipe sleeve which is 2 pipe sized bigger. waterproofing joints at the roof and around vent pipes shall be made water tight by use of....? - answerlead, copper, steel, aluminum, plastic, or approved flashing/flashing material. exterior wall opening must be made...? - answerwater tight. T or F: buried piping needs to be supported throughout it entire length. - answerTrue When backfilling the trench, that was over excavated - answerbackfill up to installation level of bottom of pipe w/sand or gravel in layers no more than 6" in depth and compacted after each placement. when a rock is encountered trenching - answerremoved to not less than 3 inches below installation level. backfill with tamped sand. when backfilling pipe systems crown of the pipe must be covered by...? - answer12 inches of tamped earth. T or F: truss members and components may be cut, drilled, notched or spliced. - answerfalse. unless they obtain approval from a design professional. hanger spacing: steel pipe - answerevery 12 ft horizontal 15 vertical where hot water piping is bundled w/cold or hot water piping... - answereach hot water pipe shall be insulated. pipe sizes great than 4 inch need restraints for drain pipes at.. - answerall changes in direction and changes in diameter greater that 2 pipe sizes. testing gauge required for 10 psi or less? - answerhas increments of .10psi or less. testing gauge required for >10 psi up to 100 psi - answerincrements of 1 psi testing gauge required for greater than 100 psi - answerincrements of 2 psi tests shall last not less than..? - answer15 minutes 2 ways you can test a drainage system. - answerin its entirety or in sections. if testing entire drainage system, all openings in piping shall be tightly closed except..? - answerthe highest opening, and system shall be filled to point of overflowing. if drainage system is tested in sections, no section shall be tested with less than..? - answera 10 foot head of water. T or F: plastic piping shall not be tested using air. - answertrue. when testing drainage system w/air, force air into system until there is... - answera uniform pressure of 5 psi or sufficient to balance a 10 inch colum of mercury. (no air test on plastic piping ) drainage and vent final test shall be... - answervisual (smoke) gravity sewer test consists of plugging building sewer at point of connection w/ public sewer, filling building sewer with water testing with not less than... - answer10 foot head of water. maintain for 15 minutes. shower liner test. fill with water not less than... - answer2 inches measured at threshold. hanger spacing: lead pipe - answercontinuous horizontal, 4 feet vertical liquid combustion byproducts of condensing appliances shall be collected and discharged to... - answeran approved plumbing fixture or disposal area in accordance with manufacturer's instructions. appliances containing evaporator or cooling coils must be provided with... - answercondensate drain systems. condensate disposal piping shall maintain a horizontal slope in the direction of discharge not less than - answer1/8 unit vertical in 12 units horizontal (1 percent slope) sheet copper for general applications shall not weigh less than... - answer12 oz per sq. ft. T or F: separate facilities shall be required for dwelling units and sleeping units. - answerfalse separate facilities are not required in structures or tenant spaces with a total occupant load including employees and customers of... - answer15 or fewer. separate facilities are not required in Mercantile occupancies in which the max occupant load is.. - answer100 or fewer in occupancies other than malls, the public/employee toilet facilities shall be located...? - answerno more than 1 story above or below and path of travel not more than 500 feet. where should public and employee toilet facilities be located in malls? - answernot more than 1 story above or below with path of travel no more than 300 feet. what type of facilities shall be in excess of required minimum? - answerpay facilities T or F: egress door for multiple occupant toilet room other than family or assisted use rooms should be lockable from the inside - answerFalse directional signage to required public toilet facilities. - answerposted in a lobby,corridor, aisle or similar space so the sign can be readily seen from main entrance. drinking fountains distance from individual tenant space that doesn't have a drinking fountain. - answerwithin 500 feet of the most remote location in tenant space, and not more than one story above or below. if in a mall with

Show more Read less
Institution
Journeyman Plumbing
Course
Journeyman Plumbing










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Journeyman Plumbing
Course
Journeyman Plumbing

Document information

Uploaded on
March 7, 2024
Number of pages
19
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainbarter Kaplan University
View profile
Follow You need to be logged in order to follow users or courses
Sold
325
Member since
2 year
Number of followers
153
Documents
22254
Last sold
3 days ago
A+ STUDY MATERIALS.

We offer a wide range of high-quality study materials, including study guides practice exams and flashcards. WELCOME.

3.5

54 reviews

5
21
4
8
3
12
2
4
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions