Electrician's Licensing Exam Questions And Answers 100% Verified
Electrician's Licensing Exam Questions And Answers 100% Verified NEC Article ______ defines breakers and fuses. - answerAccording to NEC Article 100, a device that opens and closes a circuit by nonautomatic means automatically closes for a predetermined overcurrent. Annex _____ of NEC covers conduit fill. - answerAnnex C of NEC covers conduit and tubing fill for conductors and fixture wire fill. NEMA stands for National Electrical Manufacturers Association - answerTrue - NEMA is the acronym for National Electrical Manufacturers Association. What does it mean when a receptacle has "NEMA 5-20R" on it? - answerA receptacle with NEMA 5-20R on it has an amperes rating of 20, will take a NEMA-5-15P or NEMA-5-20P plug, and has a voltage rating of 125. NEC Tables 310-10 through 310-21 provide information on. - answerThe sizes of copper and aluminum wire, as well as the coating of wire that has fewer than three current carrying wires in a cable or conduit or that is buried in the earth. Which NEC tables(s) cover(s) the fill of metal boxes? - answerThe fill of metal boxes appears in NEC Tables 314.6 A and B. NEC Article _____ address EMT. - answerNEC Article 358 covers EMT. Which NEC articles cover the installation requirements for RMC, IMC, and EMT? - answerNEC Articles 342, 344, and 358 outline the installation requirements of RMC, IMC, and EMT. IN NEC 2008, what does Table 370.6A cover? - answerShows in two columns (milimeters and inches), how many wires in trade size you can place in a box. What NEC table would you go to to find trade size of conduit and raceway size? - answerChapter 9, Table 4 outlines trade size of conduit as well as raceway size. NEC Articles _____ and _____ covers metallic and non-metallic raceways in buildings. - answerNEC Article 386 covers metallic or metal raceway; NEC Article 388 covers PVC pipe. The Panel Board requirements for Application in Construction appear in NEC Article? - answerNEC Article 408 covers panel board applications. The smaller kitchen counter requiring a receptacle is _____ inches. - answerA 12in. counter requires a receptacle because it holds small appliances. What new code is needed for protection in all habitable spaces? - answerAccording to new codes, ARC fault protection is needed many additional parts of the house. A 12-foot hallway requires one receptacle to meet code. (True or False) - answerTrue, One is required, Two are suggested. NEC Article 100 is dedicated to? - answerDefinitions The main ground on a service is a(n) _____. - answerGround Rod What does NEC Section 250-28A require? - answerA main bonding jumper and a system bonding jumper. NEC section 250-28A provides information on what material can be used for a main bonding jumper. (True or False) - answerTrue A bonding screw is what color? - answerA bonding screw is green. A subpanel requires a bonding screw? (True or False) - answerFalse, A bonding screw is unneeded in a subpanel. Name the methods of sizing bonding jumpers outlined in NEC Section 250-28D. - answer1. Bonding jumper is sized not less than 12.5% of the largest phase conductor. 2. Based on the largest ungrounded service conductor. 3. Based on the largest sum of the service conductors. NEC Table _____ covers grounding electrode conductor sizing. - answerNEC Table 250.66 Which NEC reference identifies wire sizing and the temperature a wire can handle in amps? - answerNEC Tables Annex C1 and C2 identify both wire sizing and the temperature a wire can handle in amps. Define a grounding system according to NEC. - answerA gounding system is connected to the ground or to a conductive body that extends the ground conn
Written for
- Institution
- Journeyman Electrician
- Course
- Journeyman Electrician
Document information
- Uploaded on
- March 5, 2024
- Number of pages
- 18
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
electricians licensing exam questions and answers
Also available in package deal