NYC MASTER ELECTRICIAN EXAM QUESTIONS AND ANSWERS 100% ACCURATE!
Type ____ is multiconductor cable identified for use as underground service entrance cable. - ANSWER-Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less - ANSWER-Can be used only as isolating switch, shall not be opened under load Track lighting with outlets in a bathroom is not allowed because ? - ANSWER-Track lighting has receptacle Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided with an on premise fuel supply sufficient for not less than ____ hours full demand operation of the system - ANSWER-6 hours Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. - ANSWER-30 Amps Where skin effect exist the ferromagnetic envelope shall be bonded at ____. - ANSWER-Both ends GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. - ANSWER-Locking The maximum voltage drop from service point to the last over-current device in a dwelling unit? - ANSWER-4% Which of the following statements best describe the grounding requirement for central vacuum outlet - ANSWER-Accessible non current carrying metal parts are required to be connected to an equipment grounding conductor. In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system - ANSWER-Are permitted Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or similar areas - ANSWER-Do not include The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. - ANSWER-Examined or treated Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____ duplex receptacles - ANSWER-Single or two A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more patients - ANSWER-Four Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment - ANSWER-Listed fitting Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating not lower than 90°C (194°F) unless supplying a luminaiere m
Written for
- Institution
- NYC MASTER ELECTRICIAN
- Course
- NYC MASTER ELECTRICIAN
Document information
- Uploaded on
- February 13, 2024
- Number of pages
- 19
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
nyc master electrician exam questions and answers
-
nyc master electrician exam stuvia
-
type is multiconductor cable identified for u
-
track lighting with outlets in a bathroom is not a
Also available in package deal