Journeyman Final Exam Questions and Answers Which of the following conductor insulation types, if any, is/are acceptable for wiring in a fluorescent luminaire when the branch-circuit conductor passes within three (3) inches of the ballast? I. THW II. THWN 1.) neither I nor II 2.) both I and II 3.) I only 4.) II only -Answer-Answer: both I and II Table 310.4(A) on page 70-153 of the NEC® 2020 Fire pump supply conductors on the load side of the final disconnecting means and overcurrent device(s) are permitted to be routed through the inside of a building if _____. 1.) concealed within walls, floors, or ceilings that provide a thermal barrier of material that has at least a 15-minute fire rating 2.) encased in at least two (2) inches of brick or concrete 3.) installed in raceways with power conductors 4.) installed in a listed electrical circuit protective system with a 1-hour fire rating - Answer-Answer: encased in at least two (2) inches of brick or concrete 695.6(A)(2)(4) on page 70-602 of the NEC® 2020 In general, with respect to the service disconnecting means, the grounding electrode conductor shall be connected to the grounded service conductor on _____. I. the supply side II. the load side 1.) both I and II 2.) I only 3.) II only 4.) either I or II -Answer-I only 250.24(A)(5) on page 70-114 of the NEC® 2020 When made up with threaded couplings, straight runs of trade size 2-inch rigid metal conduit (RMC) shall be supported at intervals of at LEAST every _____. 1.) 20 feet 2.) 14 feet 3.) 16 feet 4.) 10 feet -Answer-answer: 16 ft 344.30(B)(2) on page 70-207 of the NEC® 2020,Table 344.30(B)(2) on page 70-207 of the NEC® 2020 Where a 36 in. long conduit contains one (1) ungrounded conductor, one (1) grounded conductor, and one (1) equipment grounding conductor, the conduit may be filled to a MAXIMUM of _____ of its cross-sectional area. 1.) 53 percent 2.) 31 percent 3.) 60 percent 4.) 40 percent -Answer-40 percent Chapter 9, Table 1 on page 70-695 of the NEC® 2020 Where a fuse or inverse time circuit breaker is used for overload protection for a hermetic motor-compressor, this device shall be rated at NOT more than _____ of the motor-compressor rated load-current. 1.) 115 percent 2.) 175 percent 3.) 150 percent 4.) 125 percent -Answer-125 percent 440.52(A)(3) on page 70-339 of the NEC® 2020 Nonconductive optical fiber cable may occupy the same raceway with conductors supplying lights and power, provided the operating voltage does NOT exceed _____. 120 volts 250 volts 600 volts 1000 volts -Answer-1000 Volts 770.133 on page 70-660 of the NEC® 2020 A metal electrical junction box with a flat blank plate to be installed will contain the following conductors: • six (6) size 10 AWG with THWN insulation • ten (10) size 12 AWG with THWN insulation • three (3) size 14 AWG equipment grounding conductors Which of the following listed junction boxes would have the MINIMUM volume, in cubic inches, as required by the NEC®? 40 cubic inches 43 cubic inches 36 cubic inches 49 cubic inches -Answer-40 cubic inches 314.16(B)(1) & (5) on page 70-183 of the NEC® 2020,Table 314.16(B) on page 70-184 of the NEC® 2020 - Size 10 AWG = 2.50 cu. in. x 6 wires= 15.0 cu. in. - Size 12 AWG = 2.25 cu. in. x 10 wires = 22.5 cu. in. - Size 14 AWG = 2.00 cu. in. x 1 wire = 2.0 cu. in. TOTAL = 39.5 cu. in. The classification of hazardous areas and zones, plus the wiring methods to be used, is to be determined by _____. licensed electricians qualified persons the local authority having jurisdiction engineers -Answer-qualified persons 505.7(A) on page 70-390 of the NEC® 2020 The MINIMUM size wire-type equipment grounding conductor for a 100-ampere, 120/240-volt, single-phase underground dwelling feeder whose ungrounded conductors have been increased in size from 4 AWG copper to 1 AWG copper is _____. 2 AWG copper 1 AWG copper 8 AWG copper 6 AWG copper -Answer-2 AWG copper

Show more Read less
Institution
Journeyman Electrician
Course
Journeyman Electrician









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Journeyman Electrician
Course
Journeyman Electrician

Document information

Uploaded on
February 13, 2024
Number of pages
7
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1092
Member since
2 year
Number of followers
482
Documents
33021
Last sold
2 days ago
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

238 reviews

5
95
4
38
3
54
2
20
1
31

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions