The end of the temperature sensing portion of the temperature measuring device
is submerged a minimum of __mm [__in.] into the freshly mixed concrete. -
Answer: 77mm /3in.
, ACI Concrete Field-Testing Technician - Grade I
The temperature measuring device shall be capable of accurately measuring the
temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. -
Answer: 0.5 C / +-1F / 0-50 Decrees C
The temp. measuring device shall be verified __, or whenever there is a question
of __. - Answer: Annually / accuracy
The temp of concrete may be measured in a wheelbarrow? T/F - Answer: True
The temp. of concrete may be measured in a wall form. T/F - Answer: True
A composite sample of concrete is required even if the only purpose for obtaining
the sample is to determine temp. T/F - Answer: False
What must be done to the sample container prior to sampling the concrete -
Answer: It must be dampened with water
What must be done to the concrete surrounding the temp measuring device after
the device is submerged in the fresh concrete? - Answer: Gently press the
concrete at the surface around the measuring device.
How long must the temperature measuring device remain in the freshly mixed
concrete? - Answer: At least 2 min., no longer than 5 min.