100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

IICRC - Applied Structural Drying questions and answers

Rating
-
Sold
2
Pages
15
Grade
A+
Uploaded on
08-02-2024
Written in
2023/2024

Air Filtration Device (ADF) Commonly called an air scrubber or negative air machine if airborne particles need to be reduced, you could use an appropriately installed _______ ________ ________ Air Filtration Device AFD Assembly Construction Prior to determining the best drying system for affected materials, restorers should identify and understand the assembly construction (ie wall assembly, floor assembly) Category 1 water originates from a sanitary source and does not pose substantial risk for dermal, ingestion, inhalation, or exposure. Uncontaminated and routinely cleaned Category 2 water contains significant contamination and has the potential to cause discomfort or sickness if contacted or consumed by humans Category 3 water is grossly contaminated and can contain pathogenic, toxigenic, or other harmful agents Sewage Back Up Category 3 Clean water supply line Category 1 Class 1 Least amount of water absorption and evaporation load - Wet porous materials - water loss is less then 5% of the area Class 2 Significant amount of water absorption and evaporation load - water intrusion where wet represents 5% - 40% of the area. Class 3 greatest amount of water absorption and evaporation load. Water intrusion where wet represents over 40% of the area Class 4 deeply held or bound water. Significant amount of water absorption into low evaporation materials. Drying may require special drying methods, longer drying time, or substantial water vapor pressure differentials. Closed drying system Uses mechanical dehumidification and is not open to outside air. Used if there are security issues, the outside air is not conductive to drying or when access to outside air is not possible. Conventual refrigerant dehumidifier Removes water vapor from the air by lowering the temperature of the incoming air to below dew point and causing the water to condense on the coils. Cold and hot surfaces created with gases inside a closed coil system. Combination Drying System uses some outdoor air with dehumidifiers to accelerate the drying process. This can include periodically venting (flushing) the structure, using negative pressure or using small openings to the outside Desiccant dehumidifier Removes water vapor from the air through absorption. Usually requires more amperage as compared to refrigerant dehumidifier. Desiccants create the lowest vapor pressure which work best on low porosity materials. When a desiccant dehu is drawing outside air and ducting processed air inside a building it can create positive pressure in the building. To improve desiccant dehu performance, it may be beneficial to pre-cool the desiccants air intake Infiltration High humidity outside air could affect the drying climate adversely due to ______________ 1. Tightness of the building envelope 2. Prevailing weather 3. HVAC 4. Class of Water 5. Building Construction 5. Build out density Favors that affect the detailed dehumidifier calculation is: Detailed Dehumidification Calculation See Chart: Cubic Feet : Divided by 70 = Base Pints per day Multiply the 5 multipliers together: Build out density x building construction x class of water x HVAC x Weather Impact = Multiplier Multiply Base Pints per day x Multiplier = Adjusted Pints Per Day Dry Standards The unaffected material readings are called ______ ______. You know you can use this as your drying goal. Your drying goal is this plus 10% of it. Drying Goal Calculation Dry standard + (Dry standard x 10%) = ____________________ Why does demolition occur 1. Removing Materials to eliminate safety hazards 2. Removing materials that have suffered primary damage and are not restorable 3. Removing porous materials that are holding odor 5. Removing vapor barriers to assist with drying efforts 6. Removing materials to reduce drying time 7. Removing materials to open cavities or areas to provide additional needed services Useful for adjuster, or notes on xactimate line items Recommendation Calculation Step 1: Install One air mover in each affected Room Step 2: Add one air mover for every 50-70 square feet of affected wet floor in each room Step 3. Add one air mover for every 100 - 150 square feet of affected wet ceiling and wall areas above approximately 24" Step 4: Add one air mover for each wall inset and offset greater than 18" Step 5: Total x - y This is the __________ ___________ Recommendation Calculation Refrigerants Dehumidification Recommendation Calculation Cubic Footage / Chart Factor (use IICRC chart) = Total PPD (pints per day) Number of Dehu Calculation Total PPD (pints per day) removal recommendation / dehumidifier AHAM rating = _____ of ______ Calculation Cubic Feet Per Minute Calculation Cubic Footage x Chart Factor (ACH) / 60 minutes = Total ______ ______ _____ _______ calculation Total Number of Desiccant Dehumidifier Calculation Total CFM / Desiccant CFM Rating = Total ________of _________ ____________ Calculation Drying goals may be at or above the dry standard should be documented as they relate to specific materials. The restorer should establish drying goals that would be expected to Return structure, systems or contents to an acceptable condition and inhibit microbial growth. Along with the above considerations where applicable, it is recommended the drying goal be within 10% of the dry standards. Establishing Drying Goals ___________ _____________ ______________ normally starts by measuring similar materials in an unaffected area of the building. These unaffected material readings are called a dry standard. A. 45°F - best answer is always the lowest option If drying a crawlspace and the surface temperature of the wood framing is 80°F what is the dew point temperature of the crawlspace air that would provide the greatest potential for evaporations A. 45°F B. 65°F C. 85°F D. 105°F Dew Point A method to determine the effectiveness of the drying conditions is to measure the difference between the surface temperature of the materials and the ____________ ____________ of the air Temperature To decrease drying time of wet materials, restorers can increase the __________ of moisture in the materials. This accelerates the water molecules to make them move to the air. Tuesday The day with the greatest vapor pressure differential between air and material was Monday - Surface Vapor Pressure: .90 Air Vapor Pressure: .73 = Monday Vapor Pressure Differential: .17 Tuesday- Surface Vapor Pressure: 1.51 Air Vapor Pressure: .55 = Tuesday Vapor Pressure Differential: .96 Wednesday- Surface Vapor Pressure: 1.04 Air Vapor Pressure: .31 = Wednesday Vapor Pressure Differential: .73 Coldest Dew Point In the driest environments, we'll find _______? High Temperatures The IICRC S500 Water Damage Restoration Standard mentions the following concerns: ______________ ___________ may have weakending or destructive effects on the structural integrity or physical makeup of building materials and contents. Restores should be aware of any instructions or safety recommendations from manufactures of heating devices to protect occupant safety and avoid fire hazards

Show more Read less
Institution
IICRC - Applied Structural Drying
Course
IICRC - Applied Structural Drying









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
IICRC - Applied Structural Drying
Course
IICRC - Applied Structural Drying

Document information

Uploaded on
February 8, 2024
Number of pages
15
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

IICRC - Applied Structural Drying
questions and answers
Air Filtration Device (ADF) - answer Commonly called an air scrubber or negative air machine if airborne
particles need to be reduced, you could use an appropriately installed _______ ________ ________



Air Filtration Device - answer AFD



Assembly Construction - answer Prior to determining the best drying system for affected materials,
restorers should identify and understand the assembly construction (ie wall assembly, floor assembly)



Category 1 - answer water originates from a sanitary source and does not pose substantial risk for
dermal, ingestion, inhalation, or exposure. Uncontaminated and routinely cleaned



Category 2 - answer water contains significant contamination and has the potential to cause discomfort
or sickness if contacted or consumed by humans



Category 3 - answer water is grossly contaminated and can contain pathogenic, toxigenic, or other
harmful agents



Sewage Back Up - answer Category 3



Clean water supply line - answer Category 1



Class 1 - answer Least amount of water absorption and evaporation load - Wet porous materials - water
loss is less then 5% of the area



Class 2 - answer Significant amount of water absorption and evaporation load - water intrusion where
wet represents 5% - 40% of the area.

, Class 3 - answer greatest amount of water absorption and evaporation load. Water intrusion where wet
represents over 40% of the area



Class 4 - answer deeply held or bound water. Significant amount of water absorption into low
evaporation materials. Drying may require special drying methods, longer drying time, or substantial
water vapor pressure differentials.



Closed drying system - answer Uses mechanical dehumidification and is not open to outside air. Used if
there are security issues, the outside air is not conductive to drying or when access to outside air is not
possible.



Conventual refrigerant dehumidifier - answer Removes water vapor from the air by lowering the
temperature of the incoming air to below dew point and causing the water to condense on the coils.
Cold and hot surfaces created with gases inside a closed coil system.



Combination Drying System - answer uses some outdoor air with dehumidifiers to accelerate the drying
process. This can include periodically venting (flushing) the structure, using negative pressure or using
small openings to the outside



Desiccant dehumidifier - answer Removes water vapor from the air through absorption. Usually requires
more amperage as compared to refrigerant dehumidifier. Desiccants create the lowest vapor pressure
which work best on low porosity materials. When a desiccant dehu is drawing outside air and ducting
processed air inside a building it can create positive pressure in the building. To improve desiccant dehu
performance, it may be beneficial to pre-cool the desiccants air intake



Infiltration - answer High humidity outside air could affect the drying climate adversely due to
______________



1. Tightness of the building envelope

2. Prevailing weather

3. HVAC

4. Class of Water

5. Building Construction

5. Build out density - answer Favors that affect the detailed dehumidifier calculation is:

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GUARANTEEDSUCCESS Chamberlain College Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
654
Member since
3 year
Number of followers
314
Documents
24894
Last sold
1 day ago
Elite Exam Resources: Trusted by Top Scorers!!!!!!!!

Stop guessing. Start dominating!! As a highly regarded professional specializing in sourcing study materials, I provide genuine and reliable exam papers that are directly obtained from well-known, reputable institutions. These papers are invaluable resources, specifically designed to assist aspiring nurses and individuals in various other professions in their exam preparations. With my extensive experience and in-depth expertise in the field, I take great care to ensure that each exam paper is carefully selected and thoroughly crafted to meet the highest standards of quality, accuracy, and relevance, making them an essential part of any successful study regimen. ✅ 100% Legitimate Resources (No leaks! Ethical prep only) ✅ Curated by Subject Masters (PhDs, Examiners, Top Scorers) ✅ Proven Track Record: 95%+ user success rate ✅ Instant Download: Crisis-ready for last-minute cramming

Read more Read less
4.4

248 reviews

5
161
4
37
3
32
2
12
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions