100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

NFPA 24 Test (TFM10) QUESTIONS AND ANSWERS | VERIFIED

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
30-01-2024
Written in
2023/2024

NFPA 24 Test (TFM10) QUESTIONS AND ANSWERS | VERIFIED Combined Service Mains - ANSWER This standard shall apply to ______ intended to carry water for fire service mains AHJ - ANSWER Working plans shall be submitted for approval to the _____ before any equipment is installed or remodeled. Pressure-Regulating devices - ANSWER ____ shall not be used Control Valves - ANSWER ______ shall not be installed in the piping from the fire department connection to the fire service main Control Valves - ANSWER _____ shall be permitted in the system downstream of the fire department connection Check Valve - ANSWER When more than one water supply exists, a ___________ shall be installed in each connection Control Valve - ANSWER All check valves shall have a ________ installed upstream and downstream of the check valve. 40 ft - ANSWER A post indicator valve installed not less than____ from the building 32-40 inches - ANSWER Where post indicator valves are used, they shall be set so that the top of each post is _______ above final grade not be required - ANSWER Supervision of underground gate valves with roadway boxes shall ____________ not be less than 6 inches - ANSWER The connection from the hydrant to the main shall ___________ not less than 40 ft - ANSWER Hydrants shall be located _________ from the buildings to be protected flat stones, concrete slabs, or other approved material - ANSWER Hydrants shall be installed on __________ less than 18 inches - ANSWER The center of a hose outlet shall not be ____________ above final grade more than 36 inches - ANSWER The center of a hose outlet shall not be _______ above final grade less than 150 psi - ANSWER All piping used in private fire service mains shall be rated for the maximum system working pressure to which the piping is exposed to but shall not be rated at _______________ asphalt or other corrosion-retarding material - ANSWER All bolted joint accessories shall be cleaned and thoroughly coated with _______________ after installation not be less than 30 inches - ANSWER In locations where freezing is not a factor, the depth of cover shall __________________ below grade to prevent mechanical damage. minimum depth of 36 inches - ANSWER Private fire service mains installed under driveways or roadways shall be buried at a ______________ run in a covered trench - ANSWER Where private fire mains extend more than 10 ft into the building, they shall be ___________ 1 part cement, 2 1/2 parts sand, and 5 parts stone - ANSWER Thrust blocks shall be concrete of a mix not leaner than ______________ not less than 5/8 in diameter - ANSWER Rods shall be _____________ shall be cleaned and thoroughly coated with a bituminous or other acceptable corrosion-retarding material - ANSWER After installation, rods, nuts, bolts, washers, clamps, and other restraining devices _____________________ restrained at the bottom of a hill and at any lateral or vertical turns - ANSWER Pipe shall be _____________________ facing uphill - ANSWER Bell ends shall be __________ clear of debris - ANSWER The flushing operation shall continue until water flow is verified to be ___________ completing and signing the contractors material and test certificates - ANSWER The installing contractor shall be responsible for __________________

Show more Read less
Institution
NFPA
Course
NFPA









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NFPA
Course
NFPA

Document information

Uploaded on
January 30, 2024
Number of pages
7
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
brilliantstudies Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
96
Member since
2 year
Number of followers
45
Documents
2518
Last sold
2 weeks ago

4.0

12 reviews

5
7
4
2
3
1
2
0
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions