100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Kentucky UST Certification Test Prep 2024

Rating
-
Sold
-
Pages
18
Grade
A+
Uploaded on
24-01-2024
Written in
2023/2024

Kentucky UST Certification Test Prep 2024 1. when tanks arrive at the job site, how should they be unloaded? - Answer ️️ -lifted off with a cable attached to the tank lifting lugs As an alternative lifting method, should a cable or chain be wrapped around the tank? - Answer ️️ -No, Never! When you are lifting a tank, using the lifting lugs, which of these procedures should be followed? - Answer ️️ -attach a triangle cable through the lugs with no more than a 30 degree angle from the center line. After you unload a new tank on a clean level surface at the job site what else should you do prior to inspection and pre-testing? - Answer ️️ -Chock the tank to prevent it from Rolling which of the following items should be physically checked for damage or imperfections at the job site? - Answer ️️ -Piping (steel and fiberglass) Fittings, Vents, Fillboxes, anodes, ECT.. The tanks themselves (ALL OF THE ABOVE)! STI-P3 tanks are delivered with shipping plugs in tank openings. What should be done to these plugs prior to testing? - Answer ️️ -remove the plugs and replace them with a standard threaded plug that is properly doped should dielectric bushings be installed in all openings of an STI-P3 tank? - Answer ️️ -yes on all openings what is the maximum air pressure to which a steel tank should be subjected in a pre-installation test? - Answer ️️ -5 pounds for fiberglass reinforced plastic (FRP) tanks up to 12 feet in diameter what is an acceptable air pressure to which the tanks may be subjected in a pre-installation test? - Answer ️️ -3 pounds for FRP tanks over 12 feet in diameter what is the maximum air pressure to which the tanks should be subjected in a pre-installation test? - Answer ️️ -3 pounds when you are conducting an air test on a tank the type of gauge that should be used is? - Answer ️️ -a pressure gauge with a maximum limit of 10 to 15 PSIG the proper procedure for conducting a pre-installation air test of a steel tank is to? - Answer ️️ - apply 3 to 5 pounds of pressure and soap all surfaces and weld seams visible through the coating while inspecting for bubbles. what is the proper procedure for conducting a pre-installation air test of an FRP tank Under 12 feet in diameter is to.... - Answer ️️ -apply 3 pounds of air pressure and soap all surfaces while inspecting for any sign of a leak either audible or visible in the form of bubbles on the surface a double-walled steel tank build in accordance with UL standard 58 is? - Answer ️️ -requires air testing of the interstitial space prior to installation the proper procedure for conducting a pre-installation air test of a double-walled tank is to? - Answer ️️ -pressurize the inner tank monitor the pressure for one hour and then pressurize the space between the inner and outer tanks with the air from the inner tank when shipped a steel tank is covered with a coating that is an important part of the tanks Corrosion Prevention system. "holidays" which show up in the coating at the installation site should? - Answer ️️ -should be touched up with a compatible coating after proper surface preparation touch up of holidays in a steel tank coatings at the installation site should be done....... - Answer ️️ -according to the manufacturer's instructions dielectric bushings are usually made of what? - Answer ️️ -non-metallic material factors to consider in determining the size shape and depth of a tank excavation include what? - Answer ️️ -*the tank manufacturers recommendations *the requirements for compacting bedding and backfill as well as stability of the soil *the depth of cover AKA all of the above in the absence of local requirements the recommended minimum distance between a tank excavation and adjacent structures or property lines is how many feet? - Answer ️️ -5 feet reinforcement of a steel underground tank may be required by the tank manufacturer if - Answer ️️ -the burial depth is greater than the tank diameter according to FRP tank manufacturers specifications the burial depth for an FRP tank should not exceed how many feet? - Answer ️️ -7 feet when installing a cathodically protected steel tank you should - Answer ️️ -make sure the excavation is free from material that could c

Show more Read less
Institution
UST- Underground Storage Tank
Course
UST- Underground Storage Tank










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
UST- Underground Storage Tank
Course
UST- Underground Storage Tank

Document information

Uploaded on
January 24, 2024
Number of pages
18
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BrittieDonald Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
400
Member since
2 year
Number of followers
162
Documents
20443
Last sold
22 hours ago
BrittieDonald Study Solutions.

Get Help in Your Due Online and Actual Exams, Assignments with Well Researched and Up-to date Study Materials for Guaranteed Success

3.5

89 reviews

5
41
4
13
3
7
2
5
1
23

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions