Michigan Builders License Exam 2024 Updates Questions and Answers 100% Verified
Michigan Builders License Exam 2024 Updates Questions and Answers 100% Verified Created to serve as a complete, comprehensive code regulating the construction of single-family, two-family and buildings consisting of three or more townhouse units. - Answer ️️ -IRC (International Residential Code) Administrative - Answer ️️ -First 2 chapters of code book are True - Answer ️️ -Plans or supporting documents are almost always required by the controlling authority prior to issuing a permit. T or F Yes - Answer ️️ -Does the building official have the authority to render interpretations of the code? 8 foot fence. - Answer ️️ -None of the following require a permit, EXCEPT: sidewalks and driveways tiling an 8 foot fence playground equipment False - Answer ️️ -Tables and illustrations are always supported by information found in the written code and footnotes. T or F Live load. - Answer ️️ -The amount of evenly distributed weight imposed by inhabitants, goods and removable objects on a floor or roof system is referred to as True. - Answer ️️ -If a code requirement is in the book, it is both acceptable and enforceable by the code official. T or F Figures. - Answer ️️ -Illustrations are typically referred to as Determine that buildings are built to the minimum enforceable standard. - Answer ️️ - Generally speaking, the building official's job is to True. - Answer ️️ -It is required that all manufacturer instructions be at the jobsite at the time of inspection. T or F Kitchen. - Answer ️️ -All of the following are not considered habitable spaces EXCEPT: bathrooms kitchens storage spaces closets 3. - Answer ️️ -Bathrooms must be provided with an aggregate glazing area no less than _____ square feet, half of which must be openable. 44 inches. - Answer ️️ -The maximum height of an egress window above the floor is 5.7 sq ft. - Answer ️️ -A basement bedroom must have an egress window with a clear opening of at least ______ square feet. 3. - Answer ️️ -At least one side-hinged exit door must be in each dwelling unit, and must be _____ feet wide. 30 inches. - Answer ️️ -A porch more than _____ inches above grade must be provided with 36" guards. 200. - Answer ️️ -Wall and ceiling finishes shall have a flame-spread classification of no more than ______ . 7 days. - Answer ️️ -According to code, concrete must reach at least 70% of it's ability within ____________days. 40%. - Answer ️️ -A stud used for a non-bearing partitions may not be notched more than ____% of the stud width. Additions, alterations, renovation and repairs. - Answer ️️ -The Michigan Uniform Energy code applies to new buildings as well as U-factor. - Answer ️️ -___________ is a measure of how well the window or door assembly conducts heat. The lower the number, the better insulation the assembly will provide. 50%. - Answer ️️ -Energy losses from recessed lighting fixtures can often reach ___% of the total thermal loss of a ceiling. R-3. - Answer ️️ -Michigan requires a minimum thermal resistance of ____________for mechanical system pipin
Written for
- Institution
- Michigan
- Course
- Michigan
Document information
- Uploaded on
- January 21, 2024
- Number of pages
- 50
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
michigan builders license exam 2024
Also available in package deal