CWB Level 2 Closed Book Exam Questions and 100%Correct Answers | Updated & Verified.
CWB Level 2 Closed Book Exam Questions and 100%Correct Answers | Updated & Verified. To measure the strength of a welded joint what mechanical test would you prescribe? a) A transverse weld tension test. b) A charpy test. c) A CTOD test. d) An all weld metal tension test. e) A side bend test. - Correct Answer-a) A transverse weld tension test. Select the cutting process that would provide the narrowest heat affected zone when cutting 12.5 mm (0.5 in) thick carbon steel. a) Oxy-acetylene cutting. b) Air-carbon arc cutting. c) Oxy-propane cutting. d) Plasma arc cutting. e) Laser beam cutting - Correct Answer-e) Laser beam cutting Which of the following refers to a welder test where a pipe assembly is placed vertically and the joint welded in the horizontal position without rotating the assembly? a) 1G b) 2G c) 3G d) 5G e) 6G - Correct Answer-b) 2G Which of the following imperfections is normally considered as unacceptable regardless of size or location? a) Porosity. b) Crack. c) Inadequate penetration. d) Lamination. e) Burn-through. - Correct Answer-b) Crack.