Millwright-Installation & Levelling exam 2024 with complete solutions
Most installation procedures start at the machine foundation substructure because? a. the manual says so b. the foundation introduces misalignments in the equipment c. the foundation moves d. the foundation is inconsistant correct answersb. the foundation introduces misalignments in the equipment When installing on concrete, millwrights usally start their installation on? a. level ground b. tempered ground c. the assumption that they will have to install anchor bolts d. exsiting anchor bolts correct answersd. exsiting anchor bolts Foundations are usually constructed with a. minus elevation b. positive elevation c. plane elevation d. on set elevation correct answersa. minus elevation This eliminates foundation shrinkage, 38mm is left for shims and grouting What is used to firmly secure the machine baseplate or soleplates to a concrete foundation? correct answersAnchor Bolts How far should straight anchor bolts without deformed ends be set into the foundation? a. 45mm