100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

NATE Heat Pump Questions with Correct Answers 100% Verified

Rating
-
Sold
-
Pages
14
Grade
A+
Uploaded on
07-12-2023
Written in
2023/2024

NATE Heat Pump Questions with Correct Answers 100% Verified R-22 vapor line diameters and lengths are typically specified for a... - Correct Answer Vapor pressure drop that does not exceed a 6-7psi or 6 degrees F The primary purpose of using flux when soldering copper or brass parts is... - Correct Answer To prevent oxidation The water that results from a defrost cycle of an air to air heat pump(runoff) must... - Correct Answer Drain off and away fro the outdoor coil to prevent excessive ice build up on the bottom of the coil and reduce capacity The component used to reduce sound transmission and prevent water leaks of a packaged heat pump installed on a roof is... - Correct Answer Curb Gasket On some installations, a heat pump indoor coil can be installed on an existing, operable, fossil fuel furnace. When this type of installation is done, you need to add a control so that... - Correct Answer The furnace and heat pump do not operate at the same time in normal heating When under a deep vacuum, a hermetic refrigeration compressor's motor windings could be... - Correct Answer Damaged if energized In order for an evacuation to be considered complete... - Correct Answer A heat pump refrigeration circuit should be evacuated to a vacuum pressure of 500 microns or below A system is supplied from the factory with charge for a 15 FOOT LINESET. The data plate shows the required system charge to be 5 POUNDS 10 OUNCES. The lineset uses 3/8 inch liquid line and is 25 FEET LONG. The manufacturers instruction sheet specifies 0.6 ounces of refrigerant to be added for each added foot of refrigerant line length so... - Correct Answer The total refrigerant charge for the system would be 6 pounds Drive slips are typically installed on the... - Correct Answer Shorter sides of rectangular duct

Show more Read less
Institution
NATE
Course
NATE









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NATE
Course
NATE

Document information

Uploaded on
December 7, 2023
Number of pages
14
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Winfred West Virgina University
View profile
Follow You need to be logged in order to follow users or courses
Sold
763
Member since
3 year
Number of followers
473
Documents
7414
Last sold
1 day ago
StudySmart

Revising without a good structure can be so frustrating but with StudySmart you are able to get revision questions, summary notes and exams to help you pass with flying colors

3.9

158 reviews

5
78
4
28
3
27
2
8
1
17

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions