Master Electrician License (2023/2024) Already Graded A
Master Electrician License (2023/2024) Already Graded A If the cover for an underground pull box used for circuits over 600v is not locked, bolted, or screwed into place, then it must weigh equal to 100 pounds The maximum total voltage droop on a branch circuit is 3% the floors of vaults in contact with the earth shall be of concrete that is not less then 6 inches thick according to the NEC bare live parts are guarded from the public in the following methods except protected by fireproof curtain equipment associated with the electrical installation can be located above or below other electrical equipment within their working space when the associated equipment dose not extend more then 6inches when the code uses the words it means the identified actions are allowed but not required, and may be optional shall be permitted a 120 volt 15-20 amp receptacle shall be located with in of air conditioning and refrigeration, heating systems 25 feet in the NEC the words . indicate a mandatory requirement shall not or shall be permitted as per New York city code in addition to the number of circuits required in a dwelling unit an individual branch circuit shall be provided for each receptacle air conditioner the dimensions of working space for access to live parts operating at 300 volts normally to ground where exposed to live parts on both sides of the workspace is 4 feet when leads are supplied with lampholders with lamp holders the conductor attached to the screw shell shall have a finish white or gray how many receptacles are required within the perimeter of the balcony, deck or porch with the useable . area of 20 sq ft one where conductors of different systems are installed in the same raceway, one system shall have a neutral having an outer covering of white or gray and each other system having a neutral shall have another covering of white with a color stripe other than green outlets may be installed in a dwelling unit for specific appliance such as laundry equipment. the maximum distance between this outlet and appliance 6 feet on a 4 wire delta system where the midpoint of one phase winding is grounded only the conductor shall have a higher phase voltage to ground. the conductor shall be marked orange where this code specifies that one equipment shall be ''in sight from'' ''within sight from'' or ''within sight of'',and so forth, another equipment, the specified equipment is to be visible and not more than distance from the other 50 feet a door used by personnel to exit the work space that is less than 25 feet from the work space shall swing outward with simple ease the authority having jurisdiction has the responsibility for making interpretations of rules where rear access is required to work on de-energized parts on the back of enclosed equipment a minimum working space of horizontally shall be provided 36 inches for equipment rated at 1200 amps or more and over 6 feet wide that contains overcurrent devices, switching devices, or control devices. there shall be one entrance to and egress from the required working space not less than 24'' wide and high at each end of work space. 6' 6'' receptacles outlets in floors shall not be counted as part of the required number of receptacles outlets unless located within of the wall 18'' the number of receptacles outlets for guest rooms in hotels and motels shall not be less than that required for a dwelling unit. these receptacles can be located to be convenient for permanent furniture layout but at least receptacles outlets shall be readily accessible. two at least one receptacle outlet shall be installed within of the top of a show window for each 12 linear feet measured horizontally across its length 18" an insulated grounded conductor of or smaller shall be identified by a continuous white or gray outer finish, or by three continuous white stripes on other than green insulation along its entire length 6 which of the following are not permitted for the protection of equipment in electrical vault stud walls covered with wallboard having a 3 hour rating dwelling units circuits running through another dwelling units in common areas. what percentage of change will require it to be brought up to current code 50% access openings in a manhole shall be not less than 26" receptacles outlets installed for a appliance in a dwelling unit, such as a laundry equipment shall be located within of the intended location of the appliance 6ft there shall be a minimum of one branch circuit for laundry outlet 20 amp manhole openings for personnel shall be located where they are not directly above electrical equipment or conductors in the enclosure. where this is not practicable a protective barrier or a fixed ladder shall be provided two or more small appliance branch circuits shall be provided to supply power for receptacle outlets in the dwelling unit kitchen, dining room, breakfast room, or similar dining areas 20 amp the work space in front of electrical equipment shall not be less than wide . or the width of the equipment which ever is greater 30" in locations where electrical equipment is likely to be exposed to enclosures or guards shall be so arranged and of such strength as to prevent such
Written for
- Institution
- Master Electrician License
- Course
- Master Electrician License
Document information
- Uploaded on
- November 18, 2023
- Number of pages
- 28
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
master electrician license already gra
Also available in package deal