100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

EPA 608 Type III Correct Questions & Answers(Rated A)

Rating
-
Sold
-
Pages
5
Grade
A+
Uploaded on
14-11-2023
Written in
2023/2024

A typical setting for the high pressure cut-out control on a recovery unit used for evacuating the refrigerant from a low pressure chiller is: - ANSWER C) 10 psig. A charged low pressure refrigeration system can be efficiently leak checked by: - ANSWER D) raising system pressure by heating with circulated hot water or heating blankets. The existence of air in a low pressure system, causes __________. - ANSWER C) high head pressure. Which safety precaution should be adhered to for low pressure systems? - ANSWER D) all of the above Refrigerant-11 at 14.7 PSIA will boil at about: - ANSWER B) 74.5F. When there is excessive moisture collecting in the purge unit of a low pressure refrigeration system, this indicates that the __________. - ANSWER B) the condenser or chiller barrel tubes are leaking. ASHRAE Standard 15 - 1994 requires equipment room refrigerant sensors for what safety group classification? - ANSWER D) All refrigerant safety groups When recharging a refrigeration system with R-11, what vapor pressure is necessary in the shells before charging with liquid? - ANSWER D) 16.9" Hg vacuum After reaching the required recovery vacuum on a chiller, you should: - ANSWER B) Wait for at least a few minutes to see if the system pressure rises, indicating that there is still refrigerant in liquid form or in the oil. A hydrostatic tube test kit is used to: - ANSWER D) determine if a tube leaks. When charging a chiller, refrigerant vapor is introduced into the system before charging with liquid. This is because: - ANSWER D) Liquid charged into a deep vacuum will cause the refrigerant to boil and may lower temperatures enough to freeze the water in the tubes. When evacuating a system, the use of too large a vacuum pump can cause: - ANSWER A) trapped water to freeze. On a low-pressure chiller with an open-type compressor, the ________________ is very susceptible to leaks. - ANSWER B) shaft seal

Show more Read less
Institution
EPA 608
Course
EPA 608









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA 608
Course
EPA 608

Document information

Uploaded on
November 14, 2023
Number of pages
5
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersmaster01 Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
280
Member since
2 year
Number of followers
106
Documents
14075
Last sold
2 days ago
PAPERSMASTER01

On this page you will find documents , package deals, flashcards offered by seller PAPERSMASTER01.With our documents on your side you"ll be well equipped to tackle you exams and achieve the grades you need.

3.9

71 reviews

5
22
4
33
3
9
2
3
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions