100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

FDNY S12| 53 QUESTIONS AND ANSWERS|GUARANTEED SUCCESS

Rating
-
Sold
-
Pages
5
Grade
A+
Uploaded on
25-10-2023
Written in
2023/2024

Unlawful to be installed Devices that give the physical appearance of fire protection equipment (ex. CCTV sprinkler head) Minimum amount of time records must be kept 3 years Hydro static test must be performed Every 5 years System fully out of service Tag/red Disc/White System partially out of service Tag/Red. Disc/Blue System free from defects Tag/Green. Disc/N/A S12/S15 holder may perform Visual inspections, proper notifications and record inspection results S12/S15 with Q99/01 May perform Visual inspections, test notification appliances, perform daily and weekly routine maintenance and record inspection results MFSPC Master fire suppression piping contractor MP Master plumber MFSPC w/s12/15 can Inspect, test, maintain and repair/replace system components MP with S12/15 can only work on Residential with 30 sprinkler heads or less and no booster pump Deluge system All sprinkler heads are open, pipes dry ELO extra large orifice sprinkler Orifice size greater than 1" Extended coverage sprinklers head Covers max 400sqft in light hazard and 144sqft for high hazard areas Large orifice sprinkler Orifice greater than 3/4" but smaller than 1" RTI Response time index SIN Sprinkler identification numbers required on sprinkler heads manufactured after 1/1/2000 Minimum maintained building temperature 40deg F System where water is stored in pipes. Automatic wet system System where air is stored in pipes Automatic Dry system Psi in dry system piping 15-20psi Has no water in pipes until fire/smoke is detected Pre action system Who needs to draw sketch of compactor garbage Shute sprinkler system CoF holder _____________ sprinkler heads have been recalled Cycling sprinkler heads Build up of foreign material on sprinkler head is called Loading Spare sprinkler heads for building with 300 heads 6 Spare sprinkler heads for building with 301-1000 12 Spare sprinkler heads for building with over 1000 24 Pressure tanks may have a max size of 9000 gallons each Pressure tank air psi must be kept at 75psi Air to water ratio should always be 1 air 2 water Height of Gravity tank above highest head 25 feet Every 1 foot of elevation equals xxxpsi of water pressure 0.433psi Minimum gpm for gravity tank fill pimp 65gmp Xxxxx are directly connected to sprinkler heads Branch lines Xxxxxx are directly connected to branch lines Cross mains or loop mains Xxxxxxx are directly connected to cross mains Feed risers Xxxxxxx are able to feed mains and cross mains directly Risers Pipe 1 and 1.25" diameter are required to have hangers no further than 12ft apart All other pipe diameters are required to have hangers no more than 15ft apart Hanger must be at least x inches from upright sprinkler head 3 inches Pipe diameter up to 4" needs rod x inches in diameter 3/8 Pipe 5,6,8 inches in diameter require rod to be 1/2" 10-12 inch pipe require rod to be 5/8" Standard RTI sprinkler heads have a RTI of 80 Quick response RTI sprinkler heads have RTI of 50 Sprinkler head with orange or red glass bulb 135-170 deg F temp rating Ordinary Sprinkler head with purple glass red frame 325-375 deg F temp rating Extra High Sprinkler head with yellow or green glass and white frame 175-225 deg F temp rating Intermediate

Show more Read less
Institution
123 University
Course
FDNY









Whoops! We can’t load your doc right now. Try again or contact support.

Document information

Uploaded on
October 25, 2023
Number of pages
5
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GUARANTEEDSUCCESS Aalborg university
View profile
Follow You need to be logged in order to follow users or courses
Sold
649
Member since
2 year
Number of followers
314
Documents
24734
Last sold
4 days ago
Elite Exam Resources: Trusted by Top Scorers!!!!!!!!

Stop guessing. Start dominating!! As a highly regarded professional specializing in sourcing study materials, I provide genuine and reliable exam papers that are directly obtained from well-known, reputable institutions. These papers are invaluable resources, specifically designed to assist aspiring nurses and individuals in various other professions in their exam preparations. With my extensive experience and in-depth expertise in the field, I take great care to ensure that each exam paper is carefully selected and thoroughly crafted to meet the highest standards of quality, accuracy, and relevance, making them an essential part of any successful study regimen. ✅ 100% Legitimate Resources (No leaks! Ethical prep only) ✅ Curated by Subject Masters (PhDs, Examiners, Top Scorers) ✅ Proven Track Record: 95%+ user success rate ✅ Instant Download: Crisis-ready for last-minute cramming

Read more Read less
4.4

247 reviews

5
161
4
37
3
31
2
12
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions