FDNYC G60 PRACTICE EXAM |112 QUESTIONS WITH COMPLETE SOLUTIONS|GUARANTEED SUCCESS
All torch operators, an oxigen-fuel torch using any amount of oxigen and flamable gas and fire guards must have a current Certificate of Fitness The Certificate of Fitness holder must regulate the pressure and flow of oxygen and natural gas to each torch. if the torch operator for jewelry manufacture involves any oxygen with any fuel gas containers, the operator must be a C of F holder. A Certificate of Fitness Holder must keep his or her certificate on their person or otherwise readily available for inspection by any representative of the fire Department The easiest way to extinguish a fire caused by a leak is to close the shutoff valve Permits issued by the FDNY are required to conduct the following hot work: storing, using or handling oxygen and a flammable gas, storing, using or handling any flammable gas (e.g. LPG or CNG or acetylene) in excess of 400 SCF. Storing, using or handling any oxidizing gas (e.g. oxygen) in excess of 504 SCF. For LPG, 400 SCF is approximately 47 lbs the number of LPG containers for the storage, use, handling or transportation, requiring a permit 14.1 oz = 54 cont. 16.4 oz = 46 cont. 20 lbs = 3 cont. 33.5 lbs = 2 cont. 40 lbs = 2 cont. 100 lbs = 1 cont. Portable LPG containers that are more than 16.4 oz and CNG containers with a capacity greater than 8.7 SCF must NOT stored, handled, or used indoors in the following occupancies (as defined in the Building code): residential occupancies, factory and industrial occupancies; educational occupancies; institutional occupancies, except as the commissioner may authorize by rule. Site-specific permit may be a permanent permit or a temporary permit. Permanent permits are valid for 12 months only A city-wide permit is valid up to 30 days Permits shall be readily available on the premise for inspection by Fire Department representatives. Hot work authorization should be issued by the responsible person, and it must be available for inspection by any representative of the department during the performance of the work, and for 48 hours after the work is complete FDNY permits will be posted in a central location and recorded in a log book to assist in the coordination of construction related activities. CNG Compressed Natural Gas. For Citywide hot work operations, the Owner of the premises must be notified in writing at least _____ hours in advance prior to work beginning. 48 A class A fire extinguisher fights fires from Paper How old must a candidate be in order to earn a Certificate of Fitness? 18 Years Old What type of fire is a Class B fire extinguisher used on? Oil Examples of combustibles include Newspaper An example of a flammable material would be Gasoline Fire extinguishers must be inspected once every Month A work area should be Well Ventilated A type C fire involves Live electrical equipment Automatic sprinkler heads should be covered by a damp cloth and removed after hot work A permit is required for storing a flammable gas in excess of 400 scf Acetylene burns at 3000 degrees Fahrenheit It is dangerous to use fuel gas at pressures above 15 psi A fire extinguisher must be mounted so that the top is not more than 5 feet off the floor To extinguish a fire Always approach the fire from upwind PASS stands for Pull, Aim, Squeeze, Sweep In the case of any fire, The FDNY must be notified For piped gas, the gas should be shut off first Oxygen cylinders are made of Steel A temporary permit to conduct torch operations is valid from 1 day to 12 months A hot work permit is required for welding A spark producing tool requires a Fire Guard Soldering and brazing temperatures are typically 840 degrees Fahrenheit Oxy-Acetylene can generate a temperature of up to 6000 degrees Fahrenheit An area exposed to sparks, hot slag, radiant heat, or convective heat as a result of welding is called a Hot Work Area A person holding a Certificate of Fitness who is trained and responsible for maintaining a fire watch is known as a Fire Guard Most fires are the result of sparks What should you do if ice buildup occurs on the gas cylinder itself? call 911 immediately If a Certificate of Fitness holder discovers that an oxygen regulator is defective, they should take it out of service If a gas container is unmarked, the certificate of fitness holder should take the cylinder out of service What tank condition would be cause to remove it from service? the pressure relief valve shows visible damage A control valve should be opened by hand Persons conducting Torch Operations must possess a current G-60 Certificate of Fitness A rapid, persistent chemical reaction that releases heat and light, especially the burning of a combustible substance in the presence of oxygen. A Fire A class B fire extinguisher fights fires from oil A written statement issued by the commissioner certifying that the person to whom it is issued has passed an examination as to his or her qualifications or is otherwise deemed qualified to use or supervise the storage, handling and use of a material Certificate of Fitness What type of fire is a Class A fire extinguisher used on? cardboard
Written for
- Institution
-
123 University
- Course
-
FDNY
Document information
- Uploaded on
- October 25, 2023
- Number of pages
- 11
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
Also available in package deal