NERC RC Exam | UPDATED 2024 questions and answers
NERC RC Exam | UPDATED 2024 questions and answers Common standard time period for station battery to handle outage of AC power to chargers - 8-12 hours Time to restore data exchange redundancy when redundancy testing by RC/TOP/BA deemed unsuccessful - 2 hours Transition period to backup control facility (fully functioning) - 2 hours Annual testing of backup control facility must prove to be functional for this long - 2 hours Every 2 years TO/TOP/DSP must provide how many hours of system restoration training to field switching personnel - 2 hours Every 2 years GOP's with blackstart resources shall provide how many hours of training to operating personnel responsible for startup - 2 hours BAL-002 default contingency reserve restoration period (following disturbance recovery period) - 90 minutes How often should BA calculate and record inadvertent interchange - 60 minutes/hourly How often should BA provide MW-hour meter readings to adjacent BA's - 60 minutes/hourly TLR procedure (identifying TLR level and actions to be implemented) needs updating how often - 60 minutes/hourly Hourly ATC for next 48 hours calculated how often - 60 minutes/hourly During EEA2/3 the energy deficient entity needs to update the RC how often until alert is terminated - 60 minutes/hourly DOE-417 (disturbance reporting) should be completed by when - 60 minutes BA with loss of resources must submit RFI with start time no more than how far beyond the resource loss - 60 minutes Sink BA should ensure interchange modifications are submitted how soon after the modification - 60 minutes If unable to calculate ACE for this long, BA must notify RC - 30 minutes ACE cannot exceed BAAL for how long - 30 minutes If AVR, PSS, or other voltage control device status changes from normal operation, GOP must notify TOP within how long of the change (if it does not last longer than this, no reporting necessary) - 30 minutes GOP must notify TOP of change in reactive capability how quick - 30 minutes TOP should return from unknown operating state how quick - 30 minutes IROL Tv should be less than or equal to... (system should be returned to IROL within this time frame of exceeding) - 30 minutes RC completes RT assessments of SOL/IROL violations how often - 30 minutes Once BA/TOP notifies RC of emergency conditions, RC has how long to notify other BA/TOP's and neighboring RC's - 30 minutes Unplanned evacuation from BES control center facility is reportable by BA/TOP/RC if it lasts longer than... - 30 minutes Complete loss of communication (including backup) is reportable if it lasts longer than... - 3
Written for
- Institution
- NERC RC
- Course
- NERC RC
Document information
- Uploaded on
- October 15, 2023
- Number of pages
- 4
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
nerc rc exam updated 2024 questions and answers
Also available in package deal