100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Michigan Journeyman test | 2023/24 questions and answers

Rating
2.0
(1)
Sold
2
Pages
4
Grade
A+
Uploaded on
01-10-2023
Written in
2023/2024

Michigan Journeyman test | 2023/24 questions and answers There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG - 4 Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - 3 A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 TW. Each circuit consist of two phase conductors and one grounding conductor and one equipment grounding conductor. The maximum and pasty of each phase conductor is______. - 24 amps The volt Ampere rating of a device that consumes 14.5 A on a 240 V circuit is_____. - 3480watts A 208 V, three phase heater draws 3598 W . How many campers does the heater draw - 10 The underwater light fixture shall be installed at least ________inches below the water level - 18 A general purpose receptacle shall not be installed on the_________ - Offense directly south of the pool A junction box for a 124 wet niche fixture shall be at least_______Inches above the ground - 4 A GFCI protected_______ receptacle for the pump motor May be installed on the south side of the dwelling unit dedicated grounding type - Dedicated receptacle A metal fence installed within________Feet of a pool Shall be bonded - 5 The feed to the wet niche fixture shall be installed in - Rigid brass A 15 or 20 amp receptacle Shall be located within_____Feet of a rooftop air conditioner - 25 In a commercial building the minimum size ungrounded service entrance conductor for 120 Dash 240 V single phase 200 amp service is - 3/0 thwn copper The minimum service for a one family dwelling Shall be - 100amps Type _____ Cable is not permitted for service entrance conductors - UF A comb rated 4750 W , 208 V 3 phase draws ________ amps - 13.2 Direct burial cable emerging from the ground and subject to physical damage shall be installed in_________. - Schedule 80 PVC A high impedance grounded system is limited to systems operating as _________volts or above. - 480 And expansion joint is required for non-metallic conduit when the temperature changes for -15° to 105°F, the thermal expansion for 100 feet or rigid nonmetallic conduit is________ inches - 4.87 The voltage rating for communication cable shall not be less than________volts? - 300 V The direction or rotation of a three phase motor can be reversed by and are changing any________ leads - 2 A(n) _________ Receptacle may be included on a small appliance branch circuit ? - Electric clock/gas range A light fixture that weighs more than _______pounds shall be supported independently of the fixture junction box - 50 Disconnecting means shall be provided on a supply side of all carriage fuses of any voltage where? - Accessible to other than qualified persons Furnaces shall be supplied by______________ Branch circuits? - Individual A screw connecting the neutral bar or a grounded system to the service equipment enclosure is called the_________? - Main bonding jumper The minimum size rigid metal conduit for a commercial service rated for 150 A 120/240 V three wire single phase using THWN wire is______? - 1 1/2 Round boxes shall not be used where conduit's or connectors fastened to the_____ of the box. - Side In a house, a garbage disposal may be installed with a cord and attachment plug if the cord is______. - No less than 18 inches no more than 36 inches Direct burial cables rated above ________volts shall be shielded. - 2000 V When two ground rods are installed, they shall be separated by a minimum of ______ feet - 6 The minimum vertical clearance for

Show more Read less
Institution
Michigan Journeyman
Course
Michigan Journeyman








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Michigan Journeyman
Course
Michigan Journeyman

Document information

Uploaded on
October 1, 2023
Number of pages
4
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Michigan Journeyman test | 2023/24 questions and answers There are six cond uctors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG - 4 Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - 3 A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 TW. Each circuit consist of two phase conductors and one grounding conductor and one equipment grounding conductor. The maximum and pasty of each phase conductor is______. - 24 amps The volt Ampere rating of a device that consumes 14.5 A on a 240 V circuit is_____. - 3480watts A 208 V, three phase heater draws 3598 W . How many campers does the heater draw - 10 The underwater light fixture shall be installed at least ________inches below the water level - 18 A general purpose receptacle shall not be installed on the_________ - Offense directly south of the pool A junction box for a 124 wet niche fixture shall be at least_______Inches above the ground - 4 A GFCI protected_______ receptacle for the pump motor May be installed on the south side of the dwelling unit dedicated grounding type - Dedicated receptacle A metal fence installed within________Feet of a pool Shall be bonded - 5 The feed to th e wet niche fixture shall be installed in - Rigid brass A 15 or 20 amp receptacle Shall be located within_____Feet of a rooftop air conditioner - 25 In a commercial building the minimum size ungrounded service entrance conductor for 120 Dash 240 V single phase 200 amp service is - 3/0 thwn copper The minimum service for a one family dwelling Shall be - 100amps Type _____ Cable is not permitted for service entrance conductors - UF A comb rated 4750 W , 208 V 3 phase draws ________ amps - 13.2 Direct burial cable emerging from the ground and subject to physical damage shall be installed in_________. - Schedule 80 PVC A high impedance grounded system is limited to systems operating as _________volts or above. - 480 And expansion joint is requir ed for non -metallic conduit when the temperature changes for -15° to 105°F, the thermal expansion for 100 feet or rigid nonmetallic conduit is________ inches - 4.87 The voltage rating for communication cable shall not be less than________volts? - 300 V The direction or rotation of a three phase motor can be reversed by and are changing any________ leads - 2

Reviews from verified buyers

Showing all reviews
7 months ago

Multiple answers are incorrect

7 months ago

@joetraynham Thanks for review our team is looking to fix that.

2.0

1 reviews

5
0
4
0
3
0
2
1
1
0
Trustworthy reviews on Stuvia

All reviews are made by real Stuvia users after verified purchases.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUVEX NURSING
View profile
Follow You need to be logged in order to follow users or courses
Sold
720
Member since
2 year
Number of followers
312
Documents
15137
Last sold
6 hours ago
STUVATE - STUVIA USA

Our store is a comprehensive destination for buying and selling a variety of documents. we offer a vast range of documents that cater to different needs and requirements, our documents are well-researched, accurate, and of high quality, ensuring customer satisfaction. whether you are looking for legal documents, academic papers, business reports or miscellaneous documents we`ve got you covered.

3.8

109 reviews

5
42
4
29
3
22
2
7
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions