100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Sterile Processing Final Exam Practice Test Chapters 1, 2, 3, 4, 5, 6, 8, 10, 11, 12, 13 | 225 questions and answers 2023/24

Rating
-
Sold
-
Pages
29
Grade
A+
Uploaded on
29-09-2023
Written in
2023/2024

Sterile Processing Final Exam Practice Test Chapters 1, 2, 3, 4, 5, 6, 8, 10, 11, 12, 13 | 225 questions and answers 2023/24 An osteotome is (A) used to cut or shave bone. (B) a retractor. (C) a hemostatic forceps. (D) none of the above. - A When returning loaner items to the vendor (A) all items should be completely assembled, tested and sterile. (B) trays should be returned immediately after point-of-use cleaning.(C) all items should be cleaned and decontaminated. (D) trays should be terminally sterilized before returning them to the vendor. - C The first goal of creating an instrument pack is (A) obtain the proper packaging container for the pack. (B) decide on the order of instrument placement. (C) create a pack that meets user needs. (D) create a pack that makes the physician happy. - C Positive air flow means when the door is opened, air flows out instead of into the area. (A) True (B) False - A Molds, mushrooms and yeast are common (A) gram-negative organisms. (B) fungi. (C) gram-positive organisms. (D) prions. - B The surgery of the ear that reconstructs the eardrum so sound waves can be sent to the middle ear (A) tympanoplasty. (B) stapedectomy. (C) auditory implantation. (D) myringotomy. - A Dark areas on the lens of an endoscope are? (A) Debris (B) Light-emitting diode optics (C) Light-emitting diode bulbs (D) Damaged light fibers - D Soiled instruments and other items are received in the (blank) area of the Central Service department. (A) preparation (B) packaging (C) decontamination (D) sterilization - C Which of the following statements about the use of mechanical washers is NOT true? (A) Multi-level trays should be separated (B) Trays with lids should be opened (C) Instruments should be disassembled and opened (D) All items should be washed on the same cycle - D Agency which may intervene in a matter of worker protection even if there are no specific regulations covering the situation. (A) Occupational Safety and Health Administration (B) Environmental Protection Agency (C) U.S. Food and Drug Administration (D) Association of periOperative Registered Nurses - A Laser finished instruments are coated with durable protective finish that cannot be chipped or scratched. (A) True (B) False - B Healthcare-associated infections are (A) most likely to occur during a surgical procedure. (B) caused by drug resistant organisms. (C) those without known cures. (D) those which occur in the course of being treated in a healthcare facility. - D Viruses are larger than bacteria. (A) True (B) False - B The system that gives the body shape and support (A) muscular system. (B) nervous system. (C) skeletal system. (D) circulatory system. - C Electronic testing of laparoscopic insulation should be done (A) in the decontamination area prior to cleaning. (B) in the clean assembly area prior to set assembly. (C) at the factory or onsite repair unit. (D) in the operating room at the end of the procedure. - B Count sheets (A) describe each instrument in detail. (B) are used only for Operating Room trays and large procedure packs. (C) provide a detailed list of tray contents. (D) all the above. - C Central Service technicians must wear special attire referred to as (blank) to minimize their exposure to bloodborne pathogens and other contaminants. (A) PPE (B) OSHA (C) TPA (D) CDC - A The temperature in the decontamination area should be between (A) 55 to 60 degrees Fahrenheit (B) 58 to 62 degrees Fahrenheit (C) 60 to 65 degrees Fahrenheit (D) 65 to 70 degrees Fahrenheit - C Staphylococcus is classified as a gram-positive bacteria. (A) True (B) False - A Kerrison/laminectomy rongeurs should be tested using (A) tissue paper. (B) a plastic dowel rod. (C) rubber testing material. (D) an index card. - D Which of the following should be used to thoroughly rinse (remove) all traces of disinfectant from an endoscope's channels? (A) Forced air (B) Water containing approved sterilant (C) Treated water (D) A heated glutaraldehyde - C The prefix hemi- (A) means near. (B) is a suffix. (C) means half. (D) means around. - C The term septorhinoplasty means (A) surgery of a muscle wound. (B) surgical repair of the nose. (C) removal of a cyst. (D) incision of the stomach. - B Powered surgical instrument air hoses should be pressurized for proper inspection. (A) True (B) False - A Arthroscopy instruments are used during (A) robotic surgery. (B) laparoscopic surgery. (C) joint surgery. (D) all the above. - C The term itis means (A) illness. (B) inflammation. (C) study of. (D) pain. - B Bacteria that do not require oxygen to live are called (A) pathogenic. (B) anaerobic. (C) aerobic. (D) vibrio. - B Instruments (Scissors) with tungsten carbide jaws can be easily identified by (A) the diamond serration pattern on the instrument jaws. (B) the black handles on the instrument. (C) the gold handles on the instrument. (D) the self-retaining lock on the instrument shaft. - C Robotic instruments (A) do not come apart for cleaning. (B) have mechanical and electrical components in the proximal end of the instrument. (C) are heavier than standard laparoscopic instruments. (D) are all of the above. - D The mechanical process by which an ultrasonic cleaner works is called cavitation. (A) True (B) False - A Clean multi-part instruments that have been assembled to test for functionality should (A) remain assembled for sterilization. (B) be disassembled and placed in peel packs for sterilization. (C) be disassembled and sterilized following manufacturer's Instructions for Use. (D) broken down and place

Show more Read less
Institution
Sterile Processing Technician Certification
Course
Sterile processing technician certification










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Sterile processing technician certification
Course
Sterile processing technician certification

Document information

Uploaded on
September 29, 2023
Number of pages
29
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUVEX NURSING
View profile
Follow You need to be logged in order to follow users or courses
Sold
734
Member since
2 year
Number of followers
313
Documents
15272
Last sold
2 days ago
STUVATE - STUVIA USA

My store is a comprehensive destination for buying and selling a variety of documents. we offer a vast range of documents that cater to different needs and requirements, our documents are well-researched, accurate, and of high quality, ensuring customer satisfaction. whether you are looking for legal documents, academic papers, business reports or miscellaneous documents we`ve got you covered.

3.8

114 reviews

5
45
4
29
3
23
2
7
1
10

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions