Electrical Journeyman Test 2023| 192 Questions| With Complete Solutions
A fixed light will be allowed to be 30 amp provided the socket is rated ____ duty. a. Light b. Medium c. Heavy d. Extra Heavy correct answer: c. Heavy From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in subsection (3), and individual other than an individual who is licensed under this article and ______________ working under the direction of a holder of an electrical contractors licence, shall not in any manner undertake to execute any electrical work". correct answer: ...And employed by and... A box with (2) 14/3 NM, one yoke, and a clamp requires a minimum or _____ cubic inches. a. 16 b. 18 c. 20 d. 22 correct answer: c. 20 NM Cable in a 2x4x2.5 plastic box will not require a cable clamp if secured within _____ inches of the box. a. 8 b. 12 c. 16 d. 20 correct answer: a. 8 A box with #10 AWG THHN will require a free space of _____inches. a. 2 b. 2.25 c. 2.5 d. 3 correct answer: c. 2.5 (See Table 314.16 (B).) A mobile home with 100 amp service will require service conductors of ____ AWG. a. #4 b. #3 c. #2 d. #1 correct answer: a. #4 (See 550.33 (B) and 310.15 (B)(7).) A service with (4) 4" PVC conduits with (4) 800KCMIL feeder in each will require a main bonding jumper of what AWG? a. 4/0 b. 1/0 c. 250 KCMIL d. 500 KCMIL correct answer: d. 500 KCMIL (See Table 250.102 (C)(1) and Chapter 9 Table 8 A conduit protecting the grounding electrode conductor shall be bonded to the ____ at both ends. correct answer: Grounding Electrode Conductor (See 250.66(E)(1).) A grounding electrode encased in concrete shall be _____ft long and _____ in circumference. a. 8ft, 5/8" b. 12ft, 1⁄2" c. 20ft, 1⁄2" d. Something else... correct answer: c. 20ft, 1⁄2" (See 250.52(A)(3).) The required outlet for an in-ground pool shall be mounted _____ a. On the wall of a building 21 feet from waters edge b. On a balcony 8 feet above water level c. On a support 3 feet from waters edge d. On a post 6'6" above grade level correct answer: d. On a post 6'6" above grade level (See 680.22(A)(1).) Permanently installed pool motors shall have a cord length of_____ a. 3ft b. 6ft c. 12ft d. 20ft correct answer: a. 3ft (See 680.21 (A)(3).)
Written for
- Institution
- Master Electrician
- Course
- Master Electrician
Document information
- Uploaded on
- August 15, 2023
- Number of pages
- 24
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
electrical journeyman test 2023| 192 questions| wi
Also available in package deal