When a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval for testing? <<Ans>> 18 months When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum mounting height from the floor? <<Ans>> 66 inches Elevator lobby smoke detectors shall be mounted within a maximum of which distance from the center-line of the door? <<Ans>> 21 feet At minimum, when working near power lines with voltage of 600 volts and lower, an aerial lift operator shall maintain which distance from the lines? <<Ans>> 10 feet The use of unprotected EMT shall be permitted under which conditions? <<Ans>> when in direct contact with the earth According to NFPA 70, what is the maximum unsupported length of 1/2-inch flexible metallic conduit where flexibility is required after installation? <<Ans>> 4 1/2 feet What is the maximum bend (in degrees) permitted in a conduit run between outlet boxes? <<Ans>> 360 Degrees If the primary power is disconnected and the fire alarm system goes into an alarm condition, what is the minimum acceptable time for secondary power to operate the voice evacuation systems? <<Ans>> 15 minutes A riser room temperature switch should activate when the temperature falls below which level? <<Ans>> 40 degrees F According to NFPA 72, what is the maximum sound pressure level permitted in a space with notification appliances? <<Ans>> 110 dBA What is the minimum interval for testing a single-station smoke detector in multifamily units? <<Ans>> Annually Where should a technician install a detector in relation to beam that is less than 12 inches deep and less that 8 feet in center? <<Ans>> At the bottom of the beam An existing fire alarm cable in a drop ceiling will be spliced. which one of the following splice locations will comply with NFPA 70? <<Ans>> secured inside a listed box or enclosure Which function shall be tested for each newly installed smoke detector? <<Ans>> smoke entry? An 180 foot long corridor is 10 feet wide, with a smooth 10 foot ceiling, interrupted by 4-inch beams spaced every 10 feet. How many heat detectors with a listed 30 foot spacing are required? <<Ans>> 6 heat detectors At which height must cables be physically protected when being installed within an exposed ceiling? <<Ans>> 7 feet When shall smoke detectors be installed during the construction process? <<Ans>> After the final cleanup of all trades Where structural members are provided, intermediate metal conduit shall be secured within which maximum distance from an outlet box" <<Ans>> 3 feet The requirement forbidding fire alarm circuits from being T-tapped, unless indicated by the manufacturer's instructions, is intended to prevent which type of improper malfunction? <<Ans>> monitoring integrity of installation conductors? What is the maximum operating temperature of TW insulation? <<Ans>> 140 Degrees F, Table 310.15 (B)(16) Which type of meter is used to measure the current draw of a strobe circuit? <<Ans>> multimeter What is an acceptable document for finding information on spacing of video imaging smoke detection systems? <<Ans>> shop drawings in submittal package When pulling multiple cable through a junction box, the installer must leave which minimum length of wire for splicing? <<Ans>> 6 inches of wire Which three of the following conditions are symptoms of a heart attack? <<Ans>> heartburn, pain in chest, shortness of breath Sprinkler water storage containers shall be supervised to indicate what the water temperature drops to which level? <<Ans>> 40 degrees F According to NFPA 72, what is the minimum separation between outgoing and returning conductors for a Class A loop that is horizontally placed down to an 8 foot-wide corridor? <<Ans>> 4 feet of separation According to NFPA 72, a public emergency alarm reporting system shall operate its emergency power source for which minimum time period? <<Ans>> 10 minutes Where shall employers post a safety data sheet? <<Ans>> in the technician's work area

Show more Read less
Institution
NICET Fire Alarm Level 1
Course
NICET Fire Alarm Level 1









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NICET Fire Alarm Level 1
Course
NICET Fire Alarm Level 1

Document information

Uploaded on
July 19, 2023
Number of pages
7
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers
$10.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
Mawseron
4.0
(1)

Also available in package deal

Thumbnail
Package deal
Nicet Exams Compilation | Verified | Guaranteed Success 100%
-
6 2023
$ 63.44 More info

Get to know the seller

Seller avatar
Mawseron University of the People
View profile
Follow You need to be logged in order to follow users or courses
Sold
6
Member since
2 year
Number of followers
3
Documents
198
Last sold
1 year ago

latest updated documents, correct, verified & graded A study materials

4.0

1 reviews

5
0
4
1
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions