add to zero.
Solution
Power absorbed by 3A source:
since this source is in parallel with the 10V source, and the current flows into the negative
terminal, P = 3A * 10V = 30W
Power absorbed by -4A source:
since this source is in parallel with the 10V source, and the current flows into the positive
terminal, P = -(-4A * 10V) = 40W
Power absorbed by 2A source:
split this one into two, considering both voltage sources:
current flows into positive terminal of 10V source, so P = -(2A * 10V) = -20W
current flows into negative terminal of 8V source, so P = 2A * 8V = 16W
total power absorbed is P = -20W + 16W = -4W
Power absorbed by 8V source:
since this source is in series with 2A source, and the 2A flows into the negative terminal, P = -
(2A * 8V) = -16W
Power absorbed by 10V source:
split this one into two, considering two current sources:
3A current source flows into negative terminal, so P = -(3A * 10V) = -30W
The other current flowing into this source can be found by applying KCL on the node that
connects the 2A and -4A source. Since there is 2A + (-4A) = -2A flowing into that node, there
must be -2A flowing out of that node and into the positive terminal of the 10V source. Therefore,
P = -2A * 10V = -20W
total power absorbed is P = -30W + (-20W) = -50W
Add the power absorbed by all sources:
30W + 40W + (-4W) + (-16W) + (-50W) = 30W + 40W - 4W - 16W - 50W = 0