California UST Service Technician part 1 Questions And Answers
If the manufacturer training no longer exist , the local angency may? - Answer Approve comparable alternat training . UST includes? - Answer Tank and connected piping What is considered and UST - Answer petroleum storage tank What UST system meets the requirements for secondary containment? - Answer Doubled wall tanks According to title 23; the following piping components if installed after July 1 1987 must have secondary containment - Answer Pressured product piping Considered "pipe" on tanks installed after July 1 2003 - Answer Pressured product piping and below ground vapor recovery Under dispenser containment (UDC) was required for all UST systems by - Answer December 31 2003 System for exchanging gas vapors in a storage tank and product in a fuel delivery truck - Answer Stage 1 vapor recovery An approved method for non visual monitoring for existing UST systems. - Answer Statistical Inventory Reconciliation (SIR) ATG must be capable for detecting a release of ? - Answer .2 gallons per hour Manual inventory reconciliation. - Answer No longer an approved method for non visual monitoring on existing UST systems Automatic line leak detectors installed on underground piping with secondary containment shall be capable of tetecting a leak of ? - Answer 3 gallons per hour at 10 psi ATG should be programmed to test the tank ? - Answer At least monthly According to PEI RP 300 a combustible gas can be used to ? - Answer Detect vapor leaks in a vapor recovery system. According to PEI RP 300. A written scope of work for vapor recovery installation should include? - Answer Construction plans Positive shut off overfill protection device must stop the flow of fuel when the tank is no more then ? - Answer 95% full According to EO VR 201 A What could cause a nozzle shut off mechanism or malfunction? - Answer Depended filter seal damage According to VR 201 A Breakaway reconnection must be ? - Answer Logged in GDF log According to PEI RP 300 the following method of documenting piping location is NOT to ? - Answer Sketch a diagram on the inside cover of vapor recovery equipment manual According to PEI RP 300 as built drawing or pictures of the underground pipping and other components shall be ? - Answer Maintained as long as UST is in service
Written for
- Institution
- California UST Service
- Course
- California UST Service
Document information
- Uploaded on
- May 30, 2023
- Number of pages
- 6
- Written in
- 2022/2023
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
- july 1 2005
-
california ust service technician part 1 questions and answers
-
service techs shall possess or work under someone who has a current certification indicating he or she has passed the an