Class A/B Operator for Underground Storage Tank Exam 2023 with complete solution
Class A/B Operator for Underground Storage Tank Exam 2023 with complete solution The Class A and Class B certification must be renewed every: Ans 5 years UST financial responsibility requirements apply to what? Ans 600 gallon used oil tank Secondary Containment is required for what? Ans New UST Systems, Piping in contact with the ground, and Replacement UST A Class A operator shall maintain the records of UST site inspections for a *minimum* of: Ans 3 years New owners of an existing UST system shall register the UST system with DEQ/LARA within what period from date of ownership? Ans 30 days UST systems with cathodic protection should be inspected for proper operation by a qualified cathodic protection tester on the following schedule: Ans Every three years UST systems with impressed current cathodic protection systems must be inspected at a minimum: Ans Every 60 days Within what period after a repair should a cathodically protected UST system be tested to ensure it is working properly? Ans 6 months Pressurized underground piping that routinely contains regulated substances shall be monitored for releases in a manner that meets what requirements? Ans Be equipped with a line leak detector, and have an annual line tightness test A suspected release must be confirmed to the DEQ/LARA within: Ans 7 days What actions are required in MUSTR when there is a spill or overfil of petroleum or hazardouz substances that result in a release into groundwater, surface water, or substance soils? Ans Notify DEQ/LARA of a confirmed release, Immediately clean up the spill or overfill, and Contain the spill To permanently close a tank, an owner and operator shall: Ans Remove the tank from the ground, Fill with an inert solid if removal jeopardizes the building structure integrity, and Empty and clean the tank by removing all liquids and accumulated sludge and purge it of all vapors If you have 100 or fewer tanks, financial responsibility is required in the aggregate the amount of: Ans $1 Million Petroleum marketers are required to have finanical responsibility to cover X dollars per occurence. X is.... Ans $1 Million Can an owner use pollution liability insurance as a means of financial responsibility? Ans Yes An automatic tank gauge must be able to detect a leak of X gallons per hour. X is: Ans 0.2 gallons per hour Statistical Inventory reconciliation (SIR) analyzes the following as a means of leak detection: Ans Inventory, Delivery and Dispensing Manual tank gauging can be used as the 'sole' means of a leak detection for tanks that are X gallons or less in capacity. X is: Ans 550 gallons Check if the following statement is true or false: "A third party evaluation of a statistical inventory reconciliation is good for any type of tank and product." Ans False Automatic line leak detectors must be able to detect a leak of at least X gallons per hour at a line pressure of 10 psi witin one hour. X is: Ans 3 gallons per hour Line testing of piping shall be capable of detecting X gallons per hour leak rate at 1 and a half times the operating pressure. X is: Ans 0.1 gallons per hour What actions are not appropriate when when the owner/operator becomes aware of a spill or overfill? Ans Drain the spill to the storm sewer or nearby ditch Upon confirmation of a release to the soil/groundwater/surface water the operator shall: Ans Report the release to the DEQ within 24 hours, by fax or phone
Written for
- Institution
- Class A/B Operator for Underground Storage Tank
- Course
- Class A/B Operator for Underground Storage Tank
Document information
- Uploaded on
- May 18, 2023
- Number of pages
- 9
- Written in
- 2022/2023
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
class ab operator for underground storage tank exam 2023 with complete solution
Also available in package deal