CCHT WATER questions with complete solution rated A+ passed
CCHT WATER questions with complete solution rated A+ passed CHLORINE TESTING - correct answer REVERSE OSMOSIS (RO) MACHINES RUNS 15 MINUTES BEFORE PERFORMING ANY TOTAL CHLORINE TESTING 100 ML - correct answer THE CORRECT AMOUNT OF WATER TO COLLECT FOR TOTAL CHLORINE TESTING RPC ultra low total chlorine strips - correct answer STRIPS USED FOR CHLORINE TESTING HOW LONG ARE RPC STRIPS - correct answer IMMERSED IN SAMPLE WATER FOR 60 SECONDS WHEN SHOULD CHLORINE BE TESTED - correct answer PRIOR TO TREATMENTS IN THE MORNING AND EVERY 3-4 HOURS WHILE PATIENTS ARE DIALYZING RPC ULTRA -LOW TOTAL CHLORINE STRIPS TEST - correct answer CHLORINE IN THE WATER AFTER CARBON TANK AND POST RO 0.00 to 0.09 ppm - correct answer total chlorine levels that are patient safe AND DOCUMENT IN "TMS" OR PAPER LOG FIRST SAMPLE - correct answer SHOULD BE TAKEN FROM POST CARBON TANK 1 (WORKER ) SECOND SAMPLE - correct answer POST RO IF CHLORINE IS NOTED POST RO - correct answer DO NOT INITIATE ANY PATIENT TREATMENT, AND DOCUMENT PER FACILITY POLICY AND PROCEDURE CHLORINE BREAKTHROUGH - correct answer OCCURS POST CARBON TANK 1 (WORKER), IMMEDIATE ADDITIONAL TESTING SHOULD TAKE PLACE AFTER CARBON TANK 2 (POLISHER) CARBON TANK 2 (POLISHER) - correct answer IF TANK SHOWS RESULTS ABOVE THE ACTION LEVEL IMMEDIATELY STOP TREATMENTS BYPASS - correct answer YOU WILL PUT PATIENTS IN THIS IF CARBON TANK 2 (POLISHER) TEST POSTIVE FOR CHLORINE , DOCUMENT TMS OR TCL- 2 LOG EVERY 2 HOURS MEDICAL DIRECTOR - correct answer AFTER CHLORINE BREAKTHROUGH , WHO MUST APPROVE TO RESUME NORMAL OPERATION AND SIGN INTO TMS OR TCL -2 LOG WHO TO NOTIFY IF CHLORINE BREAKTHROUGH - correct answer CLINICAL MANAGER, TECHNICAL SERVICES , MEDICAL DIRECTOR AND DIRECTOR OF OPERATIONS WATER HARDNESS - correct answer WATER EXISTING THE WATER SOFTENR PARTS PER MILLION (PPM) - correct answer HOW WATER HARDNESS IS MEASURED 20 PPM - correct answer ACCEPTABLE LIMITS FOR WATER HARDNESS POST SOFTNER HOW OFTEN WATER SOFTNER TEST DONE - correct answer THERE ARE 2 WATER HARDNESS TEST DONE DAILY, UNDER NORMAL OPERATING CONDITIONS HARDNES STRIPS TEST FOR - correct answer CALCIUM AND MAGNESIUM SAMPLE CONTAINERS ARE - correct answer RINSED 3 TIMES BEFORE A SAMPLE IS COLLECTED FOR TESTING CONDUCTIVITY METETR - correct answer PHOENIX OR MYRON METER L
Written for
- Institution
- CCHT
- Course
- CCHT
Document information
- Uploaded on
- May 12, 2023
- Number of pages
- 4
- Written in
- 2022/2023
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
ccht water questions with complete solution rated a passed
-
chlorine testing reverse osmosis ro machines runs 15 minutes before performing any total chlorine testing
-
100 ml the correct amount of wat
Also available in package deal