Since 1992, the United States Department of Energy has required that all furnaces sold and installed from that date on must have an AFUE of no less than: A: 70% B: 75% C: 78% D: 80% CORRECT ANSWER C: 78%
Many pre-1992 furnaces have efficiencies around _______. A: 10% B: 40% C: 60% D: 80% CORRECT ANSWER C: 60%
Today, furnaces with AFUE ratings greater than _____ are available. A: 85% B: 90% C: 100% D: 110% CORRECT ANSWER B: 90%
A thermocouple is used with: A: Intermittent pilot systems B: Direct spark ignition systems C: Glow coil ignition systems D: Standing pilot ignition systems CORRECT ANSWER D: Standing pilot ignition systems
The purpose of the gas pressure regulator is to: A: Keep the color of the flame constant B: Keep the high limit switch from tripping C: Maintain a constant gas pressure at the burner D: Allow the gas valve to operate smoothly and accurately CORRECT ANSWER C: Maintain a
constant gas pressure at the burner
The instrument used to measure outlet gas pressure is the: A: Velometer B: Anemometer C: Monometer D: Draft gauge CORRECT ANSWER C: Monometer
The regulator on a natural gas furnace should be adjusted to supply _____ inches of pressure at the burners. A: 11" B: 10" C: 3.5" D: 2" CORRECT ANSWER C: 3.5"
Burning one cubic foot of natural gas releases approximately _____ btu. A: 800 B: 1,050 C: 12,000 D: 15,000 CORRECT ANSWER B: 1,050
Under ideal conditions natural gas has an ignition temperature of _______ degrees F and a burning temperature of ________ degrees F.