Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

BACKFLOW / CROSS CONNECTION TEST PRACTICE || 2026 LATEST UPDATE!!!

Rating
-
Sold
-
Pages
5
Grade
A+
Uploaded on
12-02-2026
Written in
2025/2026

14.71 Pounds per square inch - ANSWERwhat is the means value of atmospheric pressure at sea level Backsiphonage - ANSWERA backflow condition in which the pressure in the distribution system is less than atmospheric pressure (subatmospheric) Cross Connection - ANSWERA byass arrangement or jumper connection around a backflow prevention device is considered a....

Show more Read less
Institution
Backflow Certification
Course
Backflow certification

Content preview

BACKFLOW / CROSS CONNECTION
TEST PRACTICE || 2026 LATEST
UPDATE!!!
14.71 Pounds per square inch - ANSWERwhat is the means value of atmospheric
pressure at sea level

Backsiphonage - ANSWERA backflow condition in which the pressure in the distribution
system is less than atmospheric pressure (subatmospheric)

Cross Connection - ANSWERA byass arrangement or jumper connection around a
backflow prevention device is considered a....

Both Backsiphonage and BackPressure - ANSWERA direct cross-connection is a cross
connection that is subject to ...

Pressure Vacuum Breaker - ANSWERA device designed to prevent backsiphonge,
consisting of one independently operating spring-loaded check valve and an
independently operating spring loaded air-inlet valve.

Double Check Valve Assembly - ANSWERAssembly composed of two independently
acting, approved check valves , including tightly closing resilient seated shut off valves
attached at each end of the assembly and fitted with properly located resilient seated
test cocks

False - ANSWERBackflow from a submerged inlet to a plating solution tank is
prevented only through installation of a double check valve

air gap - ANSWERThe highest possible backflow protection is provided by....

Dynamic Pressure - ANSWERthe pressure associated with the movement of a fluid

Twice the diameter of the pipe and no less than 1 inch - ANSWERAn approved air gap
shall be at what vertical distance above the overflow rim and no less than what
distance?

Absolute Pressure - ANSWERPressure measured on a scale where a perfect vacuum is
zero. th sume of gauge pressure and atmospheric pressure.

spill resistant vacuum breaker assembly - ANSWERequipped with a properly located
resilient test cock, a properly located bleed/ vent port and a tightly closing resilient
seated shot off valves attached to each end of the assembly

, Water Purveyor - ANSWERWho has the primary responsibility in cross connection
control to protect the public water supply ( containment)

True - ANSWERA reduced pressure principal is a device that can be used to protect
against pollution, contamination, back pressure and back siphonage.

Isolation - ANSWERA method of back flow prevention at the point of use of the
customer's water supply

Barometric Loop - ANSWERA vertical loop of pipe, rising to a height sufficient to
prevent back-siphonage from occurring in the potable water supply pipe. (Approximately
35 feet, depending on the weight of the atmosphere.)

15 working days - ANSWERIn Orange Cunty, a certified tester is required to submit
their test report from with in how many days of testing a backflow device?

Health and Safety Code - ANSWERWho gives the authority to LOCAL HEALTH
agencies to administer the cross connection program and tester certification program

The flood level rim of the plumbing fixture - ANSWERAn Air Gap is measured from the
exit of the piping to what?

33.9 ft - ANSWERA perfect vacuum at sea level can pull a water column approximately
how many feet?

Isolation - ANSWERBack flow prevention at the point of use is define as?

Reduced Pressure Principle Backflow Assembly - ANSWERFor Containment protection
in a high hazard situation, the minimum backflow prevention device required is

Differential Pressure - ANSWERThe difference in pressure between two locations in a
piping system

Differenteial pressure gauge - ANSWERType of equipment used to test backflow
assemblies such as RP, DC, PVB, SVB


Containment - ANSWERMethod of backflow prevention at the point of connection
(meter) of the consumers water supply

Nevada Administrative Code (NAC) 445-A - ANSWERWhat is the Legal Document in
Nevada that governs Cross Connection control and backflow prevention

The Safe Drinking Water Act ;amended 1996 - ANSWERThe Federal Guidelines that
regulate the safety of drinking water are contained in.

Written for

Institution
Backflow certification
Course
Backflow certification

Document information

Uploaded on
February 12, 2026
Number of pages
5
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • backflow
$12.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
BACKFLOW PREVENTION STUDY GUIDE (CHARLESTON WATER SYSTEMS)CORRECT 100% COMPLETE EXAM BUNDLE
-
13 2026
$ 170.37 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
shantelleG West Virgina University
View profile
Follow You need to be logged in order to follow users or courses
Sold
625
Member since
3 year
Number of followers
369
Documents
18116
Last sold
2 weeks ago
GOLD PREMIUM

HELLO? welcome to my store thanks for visiting this page here you are guaranteed of well revised and assured EXAMS ALL GRADED A+ thus making your education journey easy and seamless . DO NOT HESITATE TO CONTACT ME IF YOU ARE IN NEED OF ANY EXAM .I AM READY 24/7 TO ASSIST YOU ALSO REFER YOUR FRIENDS.

4.0

118 reviews

5
69
4
11
3
24
2
2
1
12

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions