Since 1992, the United States Department of Energy has required that all furnaces
sold and installed from that date on must have an AFUE of no less than:
A: 70%
B: 75%
C: 78%
D: 80% ---------CORRECT ANSWER-----------------C: 78%
Many pre-1992 furnaces have efficiencies around _______.
A: 10%
B: 40%
C: 60%
,D: 80% ---------CORRECT ANSWER-----------------C: 60%
Today, furnaces with AFUE ratings greater than _____ are available.
A: 85%
B: 90%
C: 100%
D: 110% ---------CORRECT ANSWER-----------------B: 90%
A thermocouple is used with:
A: Intermittent pilot systems
B: Direct spark ignition systems
C: Glow coil ignition systems
D: Standing pilot ignition systems ---------CORRECT ANSWER-----------------D:
Standing pilot ignition systems
,The purpose of the gas pressure regulator is to:
A: Keep the color of the flame constant
B: Keep the high limit switch from tripping
C: Maintain a constant gas pressure at the burner
D: Allow the gas valve to operate smoothly and accurately ---------CORRECT
ANSWER-----------------C: Maintain a constant gas pressure at the burner
The instrument used to measure outlet gas pressure is the:
A: Velometer
B: Anemometer
C: Monometer
D: Draft gauge ---------CORRECT ANSWER-----------------C: Monometer
, The regulator on a natural gas furnace should be adjusted to supply _____ inches
of pressure at the burners.
A: 11"
B: 10"
C: 3.5"
D: 2" ---------CORRECT ANSWER-----------------C: 3.5"
Burning one cubic foot of natural gas releases approximately _____ btu.
A: 800
B: 1,050
C: 12,000
D: 15,000 ---------CORRECT ANSWER-----------------B: 1,050
Under ideal conditions natural gas has an ignition temperature of _______
degrees F and a burning temperature of ________ degrees F.