NHIE LATEST 2026 TEST PAPER QUESTIONS AND
ANSWERS GRADED A+
✔✔Foundation anchor bolts shall be at least ___ inch in diameter and shall extend a
minimum of ___ inches into the concrete or grouted cells of concrete masonry units. -
✔✔1/2 and 7 inches

✔✔Foundation anchors should be ___ from ends and ___ apart/between. - ✔✔4-12
inches and 6 feet

✔✔Floor joists are installed with the crown facing which direction? - ✔✔Up

✔✔Grounding electrode should be a minimum of ___ feet below grade - ✔✔8'

✔✔A window in a shower requires safety glazing if the bottom is ___ inches above the
shower pan. - ✔✔Less than 60" in any bathing/swimming area

✔✔Safety glazing is required where - ✔✔Panes larger than 9 square feet if all the
following are true:
Bottom less than 18" from floor
Top edge over 36" from floor
Walkway within 36" of glazing

✔✔The shower opening (or access and egress opening) should be at least _____
finish-width and ___ inches unobstructed in front of the door. - ✔✔22 inches wide
opening, and 24 horizontal inches in front of door
Also, the door should always open outward or OK if it opens both in and out.

✔✔Swale - ✔✔A graded flow path used in open drainage systems.

✔✔Non-Metallic Sheathed Cable (NM) - ✔✔_________ is a factory assembly of two or
more insulated conductors having an outer sheath of moisture resistant flame-retardant,
non-metallic material.
Commonly called Romex.
Should be supported every 4 1/2 feet, and within 1 foot of boxes and terminations.
Should have a nail guard when run closer than 1 1/4 inches from framing members.

✔✔What is the Temperature on the large refrigerant line when AC is in cool mode? -
✔✔Cool. The large (Suction) line should be cool, low pressure, returning to the
condenser outside.

✔✔Underground feeder (UF) - ✔✔Similar to Nonmetallic sheathed cable (NM), but UF
is Designed for wet locations and may be buried.

,✔✔Compressor does what? - ✔✔Compresses cool gas to superheated high pressure
gas to send through the condenser.

✔✔Condenser does what? - ✔✔The condenser takes high pressure heated gas from
the compressor, and runs the gas through coils where the fan helps remove heat from
the gas, and resulting in a warm, high pressure liquid to return to the evaporator.

✔✔When a heat pump is in heating mode, the condenser acts as? - ✔✔Reverse roles.
In heating mode, The condenser acts as An Evaporator Coil. And the evaporator acts
as a condenser.

✔✔What issue would be caused if a dryer exhaust vent terminated to the exterior
directly above the condenser? - ✔✔Poor HVAC operations. Due to the heat/water and
lint expelled from the dryer. Exhaust Must be at least 3 feet from dryer exhaust ducts.

✔✔Crawl space ventilation should be within ___ feet of each corner - ✔✔3'
At least one vent < or = 3 feet from each corner

✔✔Which type of insulation is combustible? - ✔✔Cellulose (recycled newspaper)

✔✔Vermiculite Insulation - ✔✔Looks like pea gravel. Sometimes contains asbestos if
from Libby Montana mine.

✔✔Clothes Dryer vent should be installed at least ___ feet from building opening - ✔✔3

✔✔The minimum size water service pipe shall be _____ inch. - ✔✔3/4 inch

✔✔Minimum size of toilet drain piping? - ✔✔3"

✔✔Minimum drain size for shower? - ✔✔1 1/2 inches (Some standards require 2")

✔✔The Texas Real Estate Commission assesses inspectors a fee to fund the Real
Estate
Inspection Recovery Fund based on the - ✔✔fund balance, which must remain at a
required minimum level.

✔✔The inspector should ____ and ___ their client's interest. - ✔✔Protect/Promote

✔✔There is no need for inspectors to maintain and increase their level of knowledge of
the field - ✔✔False

✔✔An inspector must complete as part of the plumbing inspection. - ✔✔Observe the
functional drainage at accessible plumbing fixtures.

,✔✔According to the Standards of Practice, oven thermostats tested at 350 degrees F
should be
accurate within what range? - ✔✔+/- 25 degrees F.

✔✔When inspecting cooling equipment, the inspector shall report all of the
following: - ✔✔1. Type of system.
2. Inadequate access to the unit.
3. Dirty evaporator coil, where accessible.

✔✔The job of the inspector is to: - ✔✔Disclose the condition of the property

✔✔The inspector should provide client with enough information: - ✔✔To assist in
determining whether to buy or not to buy

✔✔Good report writing will lower your risk, liability and exposure: - ✔✔True

✔✔All verbal comments at the inspection pertaining to deficiencies should be
included in the report: - ✔✔True

✔✔The inspector is required to have an Inspection agreement per the TREC SoP: -
✔✔False

✔✔The inspector is responsible to provide to the client any code violations: - ✔✔False

✔✔It is important that the inspector makes an observation and report to the client
his/her opinion: - ✔✔False

✔✔Any problems that in the inspector's opinion would be a health/safety issue or
major cost to the client, should be reported to the client: - ✔✔True

✔✔D.E.D. stands for: - ✔✔Detect, Evaluate, Direct

✔✔The inspector can use the Texas Standard report or others that are similar: -
✔✔False.

✔✔How does the inspector complete the form if an item required for inspection by the
Standards of Practice, such as a food waste disposer, is not present in the
property: - ✔✔Mark the NP box

✔✔The report can be changed to include circles of brackets instead of check boxes: -
✔✔False

✔✔If an item is inspected and no repairs are necessary and no comments are needed,

, how should the inspector fill it out: - ✔✔Mark the I (inspected) box for that item

✔✔The inspector may provide a different report as an attachment to the Standard
Texas Report: - ✔✔True

✔✔In a pre-printed version of the Texas Standard Report, the inspector can include a
list of items in the Comment space: - ✔✔True

✔✔An inspector may modify or delete the sections on the form, such as the language
under II.B: - ✔✔False

✔✔An inspector can pre-print the Report, with ruled lines for comments: - ✔✔True

✔✔The inspector is not required to use the TREC form for: - ✔✔1. Quality control
construction inspections
2. Inspections of remodeling
3. Re-inspections

✔✔The inspector is required to operate the TPR if one is present and will cause
damage: - ✔✔False. Not required if it may cause damage to person or property.

✔✔The inspector must report on optional systems noted in the Standard of Practice if
they are present: - ✔✔False

✔✔The inspector is required to report unit power issues: - ✔✔1. When power is not
present
2. Polarity is incorrect
3. The unit is not grounded

✔✔The inspector shall report the type of branch circuit wiring - ✔✔True

✔✔An inspector shall exclude from the inspection any part, component or system
which the inspector is not competent or qualified to inspect: - ✔✔True

✔✔An inspector must include in the report all components or systems that are found
in a home: - ✔✔False

✔✔The inspector is not required to report: Anything that is not accessible - ✔✔True

✔✔The inspector is not required to enter a crawl space where Headroom is less than: -
✔✔18 inches

✔✔The inspector is not required to enter a crawl space if the width of the

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
186
Member since
1 year
Number of followers
7
Documents
25069
Last sold
1 day ago
BOARDWALK ACADEMY

Ace Your Exams With Top Quality study Notes And Paper✅✅ ALL ACADEMIC MATERIALS AVAILABLE WITH US✅✅ LEAVE A REVIEW SO THAT WE CAN LOOK AND IMPROVE OUR MATERIALS.✅✅ WE ARE ALWAYS ONLINE AND AVAILABLE DONT HESITATE TO CONTACT US FOR SYUDY GUIDES!!✅✅ EVERYTHING IS GRADED A+✅✅ COLOUR YOUR GRADES WITH US , WE ARE HERE TO HELP YOU DONT BE RELACTANT TO REACH US

3.7

33 reviews

5
14
4
6
3
7
2
0
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions