Serve a single space.
Choose an answer
1 UPC 2 Combustion air ducts shall:
A draft hood equipped water heater is
vented through a concealed space. A final water heater inspection shall be
3 4
The portion of the vent passing made after:
through the concealed space shall:
Don't know?
Terms in this set (34)
UPC Uniform Plumbing Code
IPC International Plumbing Code
, The minimum capacity for a storage Based off the "First Hour Rating" and the number of
water heater is: bedrooms and bathrooms.
A water heater installed in a residential Located or protected from damage by a moving
garage shall be: vehicle
A final water heater inspection shall Work authorized by the permit has been installed.
be made after:
Water heaters of other than the direct- As close as possible to the chimney or gas vent.
vent type shall be located:
A three bedroom home with 2 62 Gallons
bathrooms is equipped with a gas
storage water heater. The minimum
capacity for the water heater in
accordance with the first hour rating
is:
Outdoor combustion air shall be One or two permanent openings
supplied by:
Indoor combustion air supplied by 50 cu.ft per 1,000 BTU
using the "Standard Method" requires
a minimum volume of:
Combustion air ducts shall: Serve a single space.
It shall be unlawful for any person to Obtaining a permit from the Authority Having
install, remove, or replace any water Jurisdiction
heater without first:
Vent connectors of natural draft Shall not
appliances________ be connected to
mechanical draft systems operating
under positive pressure