Guide Questions And Answers Verified
100% Correct
Dealing with a flooded area - ANSWER -Prompt removal of water and drying is
essential to prevent mold growth.
Handling HVAC systems during remediation - ANSWER -Shutting down and
sealing vents prevents the spread of mold spores through the HVAC system.
Best practice for documenting a mold remediation project - ANSWER -Detailed
records help track the remediation process and provide accountability.
Reoccupying a space after remediation - ANSWER -Reoccupying a space should
only occur after air and surface testing confirms the absence of mold.
Key indicator of successful mold remediation - ANSWER -Successful remediation
is indicated by the absence of mold spores in post-remediation testing.
Objective of post-remediation verification - ANSWER -Post-remediation
verification confirms whether the remediation was effective in removing mold.
Addressing mold growth on non-porous surfaces - ANSWER -Non-porous
surfaces can typically be cleaned effectively with soap and water.
Factors influencing mold growth - ANSWER -Temperature and humidity,
Building materials, Airflow: All listed factors can significantly impact mold
growth within a structure.
Role of negative pressure in containment setup - ANSWER -Negative pressure is
maintained to ensure that mold spores do not escape the containment area.
, Recommended method for cleaning HVAC ducts - ANSWER -Professional duct
cleaning services are equipped to handle mold contamination effectively.
Type of mold producing mycotoxins - ANSWER -Stachybotrys is commonly
known as black mold and can produce mycotoxins harmful to health.
Preventing mold growth in new buildings - ANSWER -Proper ventilation and
moisture control during construction are crucial to preventing mold growth.
Critical component of a mold remediation plan - ANSWER -Identifying and
addressing the source of moisture is essential to preventing future mold growth.
Containment - ANSWER -To prevent cross-contamination- Containment is critical
in preventing the spread of mold spores to unaffected areas, thus managing cross-
contamination.
Pressure differential during remediation - ANSWER -Negative pressure of 0.05
inches of water column
Containment barrier material - ANSWER -6-mil polyethylene sheeting
Airborne spores control method - ANSWER -High-efficiency particulate air
(HEPA) filtering
Best practice for removing contaminated materials - ANSWER -Gently cutting
and removing to minimize dust
Air monitoring timing - ANSWER -Throughout the project
Recommended respirator for mold removal - ANSWER -P100 respirator
Effective cleaning agents against mold - ANSWER -Household detergent,
Vinegar, Sodium hypochlorite (bleach). While household detergent and vinegar