in service - the status of hose stored in a hose house, on a rack or reel, or on a fire apparatus that is available and ready for immediate use at an incident. this doesnt include hose in the storage where it is not readily available to be put into service at an incident in storage - a hose that is not readily available for use because it is not at the scene of an incident and not loaded on a vehicle that can transport it to the scene in use - hose being used during fire suppression or training Impairment Coordinator - The person responsible for ensuring that proper safety precautions are taken when a fire protection system is placed out of service. The building owner shall assign an impairment coordinator to comply with the requirements of this section. In the absence of a specific designee, the owner shall be considered the impairment coordinator.

Content preview

s-13 COF FDNY study material

planned removal from service - When the system or portion of standpipe system is placed out of service
for inspection, testing, maintenance, etc. , no more than one floor can be out of service and notification
must be made to impairment coordinator



Unplanned out of service condition: - A serious defect in the standpipe or sprinkler system including, but
not limited to: an empty tank, a break or major leak in the system's water piping, inoperative or shut
water supply valves, defective fire department connections, construction related shut downs affecting
more than one floor, or complete or partial shut downs of the standpipe system, other than a shut down
for a planned removal from service.



notification for planned removal from service - no notification to the fire department is required
provided the system will fully return to service within 8 hours



notification for unplanned removal from service - reporting to owner of building and to FDNY BOROUGH
DISPATCHER



red tag on standpipe - system full out of service or partially



white disc on fire dep connection - system fully out of service



blue disc on fire dep connection - system partially out of service



Automatic Standpipe System - A standpipe system that is attached to a water supply capable of
supplying the system demand at all times and that requires no action other than opening a hose valve to
provide water at hose connections.



Auxiliary water supply - supplementary source of water for a standpipe and/or sprinkler system.

, Control Valve - valve controlling flow to water-based fire protection systems. Control valves do not
include hose valves, inspectors test valves, drain valves, trim valves for dry pip etc..



branch line - a pipe system, generally in a horizontal plane, connecting not more than one hose
connection with a standpipe



deficiency - a condition in which the application of the component is not within its designed limits or
specifications



Deluge Valve - water supply control valve intended to be operated by actuation of an automatic
detection system that is installed in the same area as the discharge devices. INTENDED USE IS MANUAL
AND AUTO



Discharge Device - A device designed to discharge water or foam-water solution in a predetermined,
fixed, or adjustable pattern. Examples include, but are not limited to, sprinklers, spray nozzles, and hose
nozzles.



dry standpipe - a standpipe system designed to have piping contain water only when the system is being
utilized (no automatic water supply)



dunnage - rooftop dunnage involves designing a raised series of beams (usually steel) bearing on posts
or bearing wall to support mechanical equipment (usually on a roof top)



Fire Department Connection - a connection, normally on the exterior of the building, through which the
fire department can pump supplemental water into the sprinkler system, standpipe, or other system
furnishing water for fire extinguishment to supplemental water supplies



fire hose - a flexible conduit constructed with one or more reinforcements (jackets) with or without a
coating or covering but with an approved non permeable lining, or with an inner reinforcement between
a protective cover and an approved non permeable lining



fire hydrant - A valve connection on a water supply system having one or more outlets and that is used
to supply hose and fire department pumps with water.

Document information

Uploaded on
January 7, 2026
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
£11.05

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Lectcaptain
5.0
(1)
Sold
4
Followers
0
Items
1002
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions