Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 12 pages
Exam (elaborations)

FDNY S15 Supervision Of Foam-Water Sprinkler Systems (Citywide) Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026

Document preview thumbnail
Preview 2 out of 12 pages

FDNY S15 Supervision Of Foam-Water Sprinkler Systems (Citywide) Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026

Content preview

FDNY S15 Supervision Of Foam-
Water Sprinkler Systems
(Citywide) Practice Exam
Questions And Correct Answers
(Verified Answers) Plus Rationales
2026


Under normal conditions, Fire Department Connections are considered as a - ANSWER - Secondary
source of water supply for standpipe and sprinkler systems.



What is the name of the device that prevents the water from freezing at the FD connection? - ANSWER -
Ball drip valve (Device)



Green Siamese caps on a FD connection would indicate the building has what type of fire protection
system installed? - ANSWER - Automatic sprinkler system



What color caps are used on a FD connection for a standpipe system? - ANSWER - Red



Under normal conditions, if the ball drip valve leaks this would indicate which of the following
conditions? - ANSWER - Lower check valve is defective



Which fire protection valve regulates the flow of water in a fire protection system? - ANSWER - OS&Y
valve (main control valve)



The OS&Y valve under normal conditions must be kept in what position? - ANSWER - Open position

, What causes the activation of a typical fusible sprinkler head? - ANSWER - Pre-determined rise in
temperature level



Who is allowed to place a tag near the main control valve when the fire protection system is out of
service? - ANSWER - Master Fire suppression Piping Contractor or master Plumber



All parts of an automatic sprinkler system exposed to freezing temperatures have to be protected by -
ANSWER - Anti-freeze solution or Automatic dry pipe system



The record (riser card) of the monthly inspection by the C of F holder should be posted at what location
on the premises? - ANSWER - Main control valve



Which of the following individuals are authorized to perform a VISUAL INSPECTION of a standpipe and
sprinkler system, make proper notification and recordkeeping ONLY? - ANSWER - S-12 or S-13 C of F
holder



What device prevents the water from freezing at the Fire Department Connection? - ANSWER - Ball drip
valve



A check- valve allows water in the system to flow in only one direction. What other purpose does it
serves? - ANSWER - Prevents the private domestic water from back flowing into the FD connection



Under normal conditions, a planned removal from service (scheduled testing, maintenance, repairs)
normally affects no more than - ANSWER - One floor(s)



When a fire protection system is partially out of service what color disc and tag is required near the FD
connection and the main control valve? - ANSWER - Blue disc and Red tag



The record for inspection, testing and maintenance of a fire protection system must be filled out by the
C of F holder and has to be kept on the premises for a minimum of - ANSWER - Three years



What is the name of the device connected to a standpipe system on every floor throughout near the
hose outlet that regulates approx. 100PSI water pressure? - ANSWER - Pressure reducing valve

Document information

Uploaded on
January 7, 2026
Number of pages
12
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
£11.05

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Lectcaptain
5.0
(1)
Sold
4
Followers
0
Items
1002
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions