100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

VA CBC Practice Exam Questions And Answers Verified 100% Correct

Beoordeling
-
Verkocht
-
Pagina's
32
Cijfer
A+
Geüpload op
24-12-2025
Geschreven in
2025/2026

VA CBC Practice Exam Questions And Answers Verified 100% Correct Welded wire reinforcement for concrete should be tapped to what MINIMUM distance? a. One full wire grid spacing plus 2 inches. b. Once full wire spacing. c. Two full wire grid spacings. d. 4 inches. - ANSWER -a. One full wire grid spacing plus 2 inches. What is the MINIMUM required platform capacity for roof deck. a. 50 pounds per square foot. b. 40 pounds per square foot. c. 60 pounds per square foot. d. 30 pounds per square foot. - ANSWER -a. 50 pounds per square foot. Inspection of high strength bolting for bearing type connections is a. Performed by an approved special inspector on a periodic basis. b. Performed daily by the contractor's personnel. c. Only required for building classified as assembly occupancy. d. Performed continuously by the project superintendent. - ANSWER -a Performed by an approved special inspector on a periodic basis. Which of the following is best where a steep roof meets vertical walls? a. Applying asphalt over the shingles and siding. b. Applying asphalt under the shingles and siding. c. Installing metal step-flashing over the building envelope. d. Installing metal step-flashing under the shingles and siding. - ANSWER -d. Installing metal step-flashing under the shingles and siding. Vertical lifelines, independent support lines, and suspensions ropes MUST a. Be attached to each other. b. Use the same point of anchorage. c. Be attached to the same point on the scaffold. d. Be attached independently of the scaffold. - ANSWER -d. Be attached independently of the scaffold. What size screw should be used to fasten metal decking? a. Number 8s or 1/8-inch diameter. b. Number 10s or 3/16-inch diameter. c. Number 12s or 1/4 - inch diameter. d. Number 14s or 5/16-inch diameter. - ANSWER -c. Number 12s or 1/4 - diameter The metal deck MUST be above what MINIMUM deck gage for welding the side laps. a. Above 22 gauge. b. Above 20 gauge. c. Above 18 gauge. d. Above 16 gauge. - ANSWER -a. Above 22 gauge. For single charge blast, the shock waves rarely travel in which direction? a. Up b. Down c. Sideways d. Path of least resistance. - ANSWER -d. Path of least resistance The nail length when used in a mechanically laminated floor or deck shall be a MINIMUM of how many times the thickness of each lamination. a. One b. One and one half c. Two and one half d. Three - ANSWER -c. Two and one half According to OSHA, upper and lower guards shall be equipped on a. Grinding machines. b. Portable, power driven circular saws. c. Hand-led crosscut table saws. d. Hand-led ripsaws. - ANSWER -b. Portable, power driven circular saws. What is the MINIMUM roof slope REQUIRED for mineral surface roll roofing? a. 1/2-inch in 12 b. 1/4-inch in 12 c. 1 inch in 12 d. 2 inch in 12 - ANSWER -c. 1 inch in 12 Which type of concrete masonry unit would be preferred for use in reinforced concrete masonry walls? a. Two core block. b. Partition block. c. Three core block. d. Tongue and grove block. - ANSWER -a. Two core block. What is the MINIMUM diameter bolt that can be used to connect k series joists to steel columns. a. 3/8 inch b. 1/2 inch c. 5/8 inch d. 3/4 inch - ANSWER -b. 1/2 inch

Meer zien Lees minder
Instelling
VA CBC
Vak
VA CBC











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
VA CBC
Vak
VA CBC

Documentinformatie

Geüpload op
24 december 2025
Aantal pagina's
32
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

VA CBC Practice Exam Questions And
Answers Verified 100% Correct
Welded wire reinforcement for concrete should be tapped to what MINIMUM
distance?

a. One full wire grid spacing plus 2 inches.
b. Once full wire spacing.
c. Two full wire grid spacings.
d. 4 inches. - ANSWER -a. One full wire grid spacing plus 2 inches.

What is the MINIMUM required platform capacity for roof deck.

a. 50 pounds per square foot.
b. 40 pounds per square foot.
c. 60 pounds per square foot.
d. 30 pounds per square foot. - ANSWER -a. 50 pounds per square foot.

Inspection of high strength bolting for bearing type connections is

a. Performed by an approved special inspector on a periodic basis.
b. Performed daily by the contractor's personnel.
c. Only required for building classified as assembly occupancy.
d. Performed continuously by the project superintendent. - ANSWER -a Performed
by an approved special inspector on a periodic basis.

Which of the following is best where a steep roof meets vertical walls?

a. Applying asphalt over the shingles and siding.
b. Applying asphalt under the shingles and siding.
c. Installing metal step-flashing over the building envelope.
d. Installing metal step-flashing under the shingles and siding. - ANSWER -d.
Installing metal step-flashing under the shingles and siding.

,Vertical lifelines, independent support lines, and suspensions ropes MUST

a. Be attached to each other.
b. Use the same point of anchorage.
c. Be attached to the same point on the scaffold.
d. Be attached independently of the scaffold. - ANSWER -d. Be attached
independently of the scaffold.

What size screw should be used to fasten metal decking?

a. Number 8s or 1/8-inch diameter.
b. Number 10s or 3/16-inch diameter.
c. Number 12s or 1/4 - inch diameter.
d. Number 14s or 5/16-inch diameter. - ANSWER -c. Number 12s or 1/4 -
diameter

The metal deck MUST be above what MINIMUM deck gage for welding the side
laps.

a. Above 22 gauge.
b. Above 20 gauge.
c. Above 18 gauge.
d. Above 16 gauge. - ANSWER -a. Above 22 gauge.

For single charge blast, the shock waves rarely travel in which direction?

a. Up
b. Down
c. Sideways
d. Path of least resistance. - ANSWER -d. Path of least resistance

The nail length when used in a mechanically laminated floor or deck shall be a
MINIMUM of how many times the thickness of each lamination.

a. One

,b. One and one half
c. Two and one half
d. Three - ANSWER -c. Two and one half

According to OSHA, upper and lower guards shall be equipped on

a. Grinding machines.
b. Portable, power driven circular saws.
c. Hand-led crosscut table saws.
d. Hand-led ripsaws. - ANSWER -b. Portable, power driven circular saws.

What is the MINIMUM roof slope REQUIRED for mineral surface roll roofing?

a. 1/2-inch in 12
b. 1/4-inch in 12
c. 1 inch in 12
d. 2 inch in 12 - ANSWER -c. 1 inch in 12

Which type of concrete masonry unit would be preferred for use in reinforced
concrete masonry walls?

a. Two core block.
b. Partition block.
c. Three core block.
d. Tongue and grove block. - ANSWER -a. Two core block.

What is the MINIMUM diameter bolt that can be used to connect k series joists to
steel columns.

a. 3/8 inch
b. 1/2 inch
c. 5/8 inch
d. 3/4 inch - ANSWER -b. 1/2 inch

, How many cubic feet of mortar would be REQUIRED for a single wythe brick
wall that is 200 square feet, has 3/8 inch joints, and 655 non-modular brick unit per
100 square feet?

a. 5.8 cubic feet.
b. 6.8 cubic feet.
c. 7.2 cubic feet.
d. 11.6 cubic feet. - ANSWER -d. 11.6 cubic feet.

According to Building Code, slopes for permanent fill shall be a MAXIMUM of

a. 20%
b. 30%
c. 40%
d. 50% - ANSWER -d. 50%

A joist chair generally carries how many reinforcing bars?

a. One bar.
b. Two bars.
c. Three bars.
d. Four bars. - ANSWER -b. Two bars.

In a mat slab, generally, where below the top of the slab is the steel located?

a. 1 inch below the top of the slab.
b. 2 inches below the top of the slab.
c. 3 inches below the top of the slab.
d. 4 inches below the top of the slab. - ANSWER -c. 3 inches below the top of the
slab.

A vapor retarder on blanket (batts) insulation should

a. Be removed when approved insulation board is used as a sub sheathing.
b. Be ventilated so it can breathe.

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TheExamMaestro Teachme2-tutor
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
121
Lid sinds
1 jaar
Aantal volgers
5
Documenten
3167
Laatst verkocht
5 dagen geleden
Exam Vault

Exam Vault is your trusted destination for high-quality exam materials and study resources. We provide a wide rage of tests and prep guides to help you succeed, whether you're preparing for academic exams, certifications, or professional assessments

3.8

13 beoordelingen

5
7
4
2
3
1
2
0
1
3

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen