What is the first thing a tech should do when arriving at a no
combustion call? -Answer-Ask how many times the customer reset the
unit.

What is the best long term solution for preventing a clogged nozzle? -
Answer--Remove any underground storage tanks.
-Install a quality oil filter.
-Cut the suction line 10" above the tank outlet to prevent sludge.

Hot water and steam valves are interchangeable. -Answer-False

When in the presence of a flame, a cad cell normally reads.. -Answer-
300-1000 ohms

If a pump is used to bring oil to a level higher than the tank, an oil
safety valve is required. -Answer-True

On a call where a hydronic heat system is putting out too much heat
on the stack, the issue may be.. -Answer--Too much draft.
-Not enough combustion air in the equipment room.
-Air leakage into chamber.

A high CO2 reading is caused by.. -Answer-Incomplete combustion

An often overlooked cause of a high CO2 reading is.. -Answer-Not
enough combustion air in the equipment room.

,When multiple pumps are wired together in a heating system, they
should be wired in.. -Answer-parallel

In a series circuit.. -Answer-Current has one path.

When 2 burners are connected to the same chimney.. -Answer-
Sufficient draft must be obtained to operate both units.

The ignition transformer is located.. -Answer-In the primary control.

When safeties are wired in series one safety will affect the operation
of the others. -Answer-True

A stack switch is no longer allowed to be installed or replaced
because.. -Answer-It's safety cutout time is higher than what is now
required.

What is a power venter and what does it do? -Answer-An electrical
device that sends fluid gases into the chimney connector.

A burner in a confined space using 1 GPH of #2 fuel oil requires what
size permanent opening for combustion air? -Answer-140"

The difference between an adjustable flame retention burner and a
fixed flame retention burner is? -Answer-Air inlets can be adjusted
Ignitor position can be adjusted
Fuel can be adjusted

Oil tank design, construction, installation and testing shall be in
accordance with.. -Answer-527 CMR 9.0

Heat is a form of.. -Answer-Energy

,If a burner is operational but the circulator pump isn't running.. -
Answer-The pump relay is not working correctly

A method of dealing with low viscosity/cold temps with #2 oil? -
Answer-Increase pump pressure/ decrease nozzle size

What is needed at the outlet of an oil tank? -Answer-Thermal safety
valve

Where do you obtain an installation permit for oil burners? -Answer-
Fire Dept

How many Btu's approximately in 1 gal of #2 fuel oil? -Answer-
140,000 btu's

Solid state ignition is superior to spark because -Answer-It is not
affected by reduced voltage

What is an installation? -Answer-The complete setting in place, ready
for operation, of an oil burner appliance together with its accessories
and equipment.

How far must a power vent terminate from an opening or window? -
Answer-4'

A pump in a one pipe system that is full of air can be self purged. -
Answer-False

List the minimum size of an oil supply line. -Answer-3/8"

, A material with electrons so loose it allows voltage to pass with little or
no resistance.. -Answer-Is a conductor

If a high limit goes off, what does a low water switch do? -Answer-
Maintains water temperature

What is flashpoint an indicator of? -Answer-Minimum temperature oil
will ignite but not continue to burn.

What travels on the inside of the wire? -Answer-Volts

What does readily accessible mean pertaining to oil burning
equipment? -Answer-Capable of being reached easily and quickly for
operation, maintenance or inspection.

What is the minimum vent pipe on an oil tank? -Answer-1 1/4"

What causes corrosion on a flue pipe? -Answer-When the flue pipe is
operating below the dew point temperature.

What are the methods to prevent oil waxing? -Answer-Put additives in
the fuel.
Add an oil line heater.
Cut with #1 fuel or kerosene.

What is the maximum tank size allowed inside unenclosed? -Answer-
660 gal

What is the purpose of a delayed oil valve? -Answer-Allows time for
the oil pump to get up to speed.
Delays oil flow to the nozzle.

Document information

Uploaded on
December 14, 2025
Number of pages
47
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$22.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
35
Last sold
-


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions