12 in; 8 ft - THE CORRECT ANSWER-When installing a heat-sensing
fire detector on the bottom of a beam, the beam must be less
than _____________ inches in depth and _____________
feet on center?


b - THE CORRECT ANSWER-Where a door is released to provide a 2-
hour fire rating directly from the smoke detector, the detector
shall be ______________
a. mounted as close as possible to the door being released
b. listed for door releasing service
c. identified for door releasing service
d. of the photoelectric type only


d - THE CORRECT ANSWER-According to NFPA, smoke detectors
installed in the ducts of HVAC systems shall initiate:
a. alarm
b. supervisory

,c. trouble
d. a or b


d - THE CORRECT ANSWER-According to the IBC, shop drawings shall
include:
a. floor plan that indicates the use of all rooms
b. annunciators
c. voltage drop calculations
d. all of the above


Master Control Unit - THE CORRECT ANSWER-The location of
remotely located power supplies shall be identified at the
________________


lower; 24 in - THE CORRECT ANSWER-Heat detectors will be installed
in an elevator hoistway to shut down power to the elevator prior
to sprinkler activation. The heat detectors need to have a
_______________ temp rating and shall be located
______________ in from the sprinkler head.


Group B - THE CORRECT ANSWER-A local community college is what
type of occupancy classification?


Group E - THE CORRECT ANSWER-What type of occupancy group for a
school below the 12th grade?


Group B - THE CORRECT ANSWER-What type of occupancy group for a
school above the 12th grade?

,Class E - THE CORRECT ANSWER-A pathway shall be designated as
_______________ (what class?) when it is NOT monitored
for integrity?


40 feet; 5 feet - THE CORRECT ANSWER-Manual fire alarm boxes shall
be installed on both sides of grouped openings over
____________ feet in width and within __________ feet of
each side of the grouped opening.


c - THE CORRECT ANSWER-A fire pump was installed in a low-rise
residential building with a required fire alarm system. What are
the requirements for the pump running signal?
a. It shall be a supervisory signal.
b. It shall be an alarm signal.
c. It shall be a supervisory or alarm signal.
d. A pump running signal is not required.


d - THE CORRECT ANSWER-A licensed electrician was hired to install
duct detectors mounted on the air ducts of a 5,000 CFM unit.
Which of the follwoing statements is true?
a. The smoke detector must be listed for use in air ducts
b. The detectors can initiate a supervisory signal
c. The detectors can initiate an alarm signal
d. All of the above

, d - THE CORRECT ANSWER-Record drawings, as-builts, shall contain
approval documetnation resulting from any
_______________?
a. variances
b. performance-based designs
c. risk analysis
d. all of the above


No - THE CORRECT ANSWER-An electrically locked door is connected
to the fire alarm system in order to unlock in the event of an
alarm. The customer has requested that a feature be added
(push button) to lock the doors even while in alarm. Is this
permitted by code?


90 seconds - THE CORRECT ANSWER-According to the 2022 edition of
NFPA 13, electric waterflow devices must activate within
_________________ of water flow beginning and continue
until the flow stops


Elevator cars - THE CORRECT ANSWER-According to teh IBC, strobe
lights/appliances shall not be required in ______________?


300v - THE CORRECT ANSWER-Communications wires (Coaxial
cables) shall have a voltage rating of not less than _________
volts


30 in - THE CORRECT ANSWER-What is the minimum workspace
width in front of electrical equipment (This allows enough room

Document information

Uploaded on
December 8, 2025
Number of pages
79
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$20.98

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GraceAlfred
4.5
(2)
Sold
12
Followers
0
Items
1350
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions