C-17 Hydraulic System Exam Questions And Correct Answers A+ Pass How many hydraulic systems are there - Answer- 4 How much pressure does each system provide? - Answer- 4000 psi When is any hydraulic system pressurized - Answer- When any system pump is operating What powers the primary and secondary hydraulic pump - Answer- Engine driven When does secondary hyd pump go active - Answer- When the primary pump px falls below 3400 When is aux activated - Answer- When both primary and secondary pump px falls below 3400 Where is No 1/2 Aux pump located - Answer- Left wheel well Where are 3/4 aux pump - Answer- Right wheel well What does the Hyd Xfer Pump do? - Answer- Permits mechanical transfer of pressure between no. 2/3 systems What function does the Xfer pump mainly serve? Where is it located? - Answer- Ensures ability to gear retract or raise cargo door/ramp if lose engine 2/3. In right wheel pod What hydraulic system incorporates the RAT? - Answer- 4 What is function if RAT - Answer- Pressurizes system 4, located in right gear pod, develops pressure to control aircraft in 4 engine flameout On ground, what systems does LM functions require - Answer- 2/3 What does HSC do? How many HSCs are there? - Answer- Monitor temps/quantity Monitor pump temps/pressure Selects pumps 2 HSCs HYD RES TEMP X - Answer- Above 121C Hot light - Answer- Case drain temp above 135C HYD QTY X LOW - Answer- Qty falls below 3.3/6.4/3.9/3.3 when at or above 27C or 1.2/3.3/1.2/1.2 below 27C HSC INOP - Answer- One of 2 HSCs failed. No auto sequencing of engine driven pumls RUD TEMP LOW - Answer- Hyd reservoir indicates rudder IFCM may be below -6C. Fluid below temp where rudder effectiveness may be degraded At what temps in hydraulic system should takeoff never be attempted - Answer- Below 7C bc may be insufficient rudder deflection in engine fail on TO How can you control transfer pump if switch light failed - Answer- From aft LM panel How many hydraulic systems power each primary flight control - Answer- 2 What would happen to primary flight controls if one of the associated sys failed - Answer- Would still operate but at a slower rate When will aux pump automatically shut down? - Answer- Low quantity (0.4) or high temp (>135) How would aux pump fail be indicated - Answer- Low px light How can failure of engine driven pump be indicated? - Answer- Low pressure or hot light How should you handle hot light on the ground? What should you do if you get a hot light in flight? - Answer- Cycle flight controls but in flight turn of system How can you tell transfer pump has failed - Answer- abnormal pressure in system being pressurized If you suspect transfer pump fail what should you do - Answer- Turn off the pump What will happen if low quantity in sys 2/3 - Answer- Affected aux pump + Xfer pump shut off How are aux pumps driven - Answer- Electrically via an AC motor How are HSCs powered - Answer- 1- bat bus 2-Dc bus 3 What is the EDV for? How does it work? - Answer- Depressurizes pump. Blocks pump outlet and commands min flow (1100 psi)

Meer zien Lees minder
Instelling
C-17 Hydraulic System
Vak
C-17 Hydraulic System









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
C-17 Hydraulic System
Vak
C-17 Hydraulic System

Documentinformatie

Geüpload op
3 december 2025
Aantal pagina's
6
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

  • c 17 hydraulic system

Voorbeeld van de inhoud

C-17 Hydraulic System Exam
Questions And Correct Answers A+
Pass
How many hydraulic systems are there - Answer- 4

How much pressure does each system provide? - Answer- 4000 psi

When is any hydraulic system pressurized - Answer- When any system pump is
operating

What powers the primary and secondary hydraulic pump - Answer- Engine driven

When does secondary hyd pump go active - Answer- When the primary pump px falls
below 3400

When is aux activated - Answer- When both primary and secondary pump px falls below
3400

Where is No 1/2 Aux pump located - Answer- Left wheel well

Where are 3/4 aux pump - Answer- Right wheel well

What does the Hyd Xfer Pump do? - Answer- Permits mechanical transfer of pressure
between no. 2/3 systems

What function does the Xfer pump mainly serve? Where is it located? - Answer-
Ensures ability to gear retract or raise cargo door/ramp if lose engine 2/3. In right wheel
pod

What hydraulic system incorporates the RAT? - Answer- 4

What is function if RAT - Answer- Pressurizes system 4, located in right gear pod,
develops pressure to control aircraft in 4 engine flameout

On ground, what systems does LM functions require - Answer- 2/3

What does HSC do? How many HSCs are there? - Answer- Monitor temps/quantity
Monitor pump temps/pressure
Selects pumps
2 HSCs

HYD RES TEMP X - Answer- Above 121C

, Hot light - Answer- Case drain temp above 135C

HYD QTY X LOW - Answer- Qty falls below 3.3/6.4/3.9/3.3 when at or above 27C or
1.2/3.3/1.2/1.2 below 27C

HSC INOP - Answer- One of 2 HSCs failed. No auto sequencing of engine driven pumls

RUD TEMP LOW - Answer- Hyd reservoir indicates rudder IFCM may be below -6C.
Fluid below temp where rudder effectiveness may be degraded

At what temps in hydraulic system should takeoff never be attempted - Answer- Below
7C bc may be insufficient rudder deflection in engine fail on TO

How can you control transfer pump if switch light failed - Answer- From aft LM panel

How many hydraulic systems power each primary flight control - Answer- 2

What would happen to primary flight controls if one of the associated sys failed -
Answer- Would still operate but at a slower rate

When will aux pump automatically shut down? - Answer- Low quantity (0.4) or high
temp (>135)

How would aux pump fail be indicated - Answer- Low px light

How can failure of engine driven pump be indicated? - Answer- Low pressure or hot
light

How should you handle hot light on the ground? What should you do if you get a hot
light in flight? - Answer- Cycle flight controls but in flight turn of system

How can you tell transfer pump has failed - Answer- abnormal pressure in system being
pressurized

If you suspect transfer pump fail what should you do - Answer- Turn off the pump

What will happen if low quantity in sys 2/3 - Answer- Affected aux pump + Xfer pump
shut off

How are aux pumps driven - Answer- Electrically via an AC motor

How are HSCs powered - Answer- 1- bat bus 2-Dc bus 3

What is the EDV for? How does it work? - Answer- Depressurizes pump. Blocks pump
outlet and commands min flow (1100 psi)

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Stuviaascorers University of Washington
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
346
Lid sinds
2 jaar
Aantal volgers
185
Documenten
10100
Laatst verkocht
4 dagen geleden
StuviaAscorers | Top Study Notes & Exam Solutions

Stuviaascorers – Your #1 Source for Top-Quality Study Materials! Struggling with exams? Stuviaascorers has got you covered! I provide expertly crafted study notes, summaries, past papers, and exam-ready answers to help you pass with flying colors. My materials are designed for clarity, accuracy, and success—so you can study smarter, not harder! Why Choose My Study Materials? Well-structured & easy to understand – No fluff, just what you need! Exam-focused & high-scoring content – Get straight to the point! Accurate answers & clear explanations – Learn with confidence! Save time & boost your grades – Study efficiently! Don’t leave your success to chance! Browse my documents and start acing your exams today!

Lees meer Lees minder
3.8

64 beoordelingen

5
30
4
11
3
11
2
2
1
10

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen